background image

CLWI-KPLEX

In-Wall Wireless Lighting Keypad, 230 Vac
Installation Guide

Description

The Crestron

®

 CLWI-KPLEX is a companion keypad for CLWI- line of dimmers and 

switches. It provides lighting and audio control from multiple locations around the home or 
office. It is designed to recall scenes, dim loads up and down, and adjust the volume using 
the customizable button layout.
The CLWI-KPLEX is shipped with a six-button configuration preinstalled on the keypad. 
The button configuration can be replaced with the included large rocker switch or any 
combination of up to two adjacent half-size rocker buttons or triple-button pads. All 
buttons are configurable for up to three discrete functions via single-press, double-press, 
and press-and-hold functionality. 
The specifications for the CLWI-KPLEX are listed below.

SPECIFICATION

DETAILS

Power Requirements

220-240 Vac, 50/60 Hz, line power

Environmental
 Temperature
 Humidity

0° to 40 °C (32° to 104 °F)
10% to 90% RH (non-condensing)

Enclosure

Mountable in a 1-gang UK (BS 4662) electrical box or 
1-gang European (DIN 49073) electrical box that is  
35 mm (1.38 in) or deeper; 
Requires a FP-INTENSE or FP-PURE style faceplate (both 
not included)

Dimensions
 Height
 Width
 Depth

72 mm (2.80 in)
72 mm (2.80 in)
32 mm (1.24 in) including front face with buttons

Weight

80 g (3 oz)

The dimensions of the CLWI-KPLEX are shown below.

72 mm

(2.80 in)

72 mm

(2.80 in)

32 mm 

(1.24 in)

51 mm

(2.00 in)

51 mm

(2.00 in)

21 mm

(0.82 in)

Additional Resources

Visit the product page on the Crestron website (

www.crestron.com

for additional information and the latest firmware updates. Use a QR 
reader application on your mobile device to scan the QR image.

Installation

To install the CLWI-KPLEX, do the following.

CAUTION:  

Use on 10 A branch circuits only.

CAUTION:  

Use 1 x 1.5 - 2.5 mm² wire that complies with BS6004:2000/IEC 60245 and 

local electrical codes.

NOTE:  

Use only copper wire rated for at least 75° C.

1.  Turn the power off at the circuit breaker.
2.  Wire the device as shown in the following diagram. Use 1 x 1.5-2.5 mm²  

(14-12 AWG) wire. Secure the connections to the CLWI-KPLEX by inserting the wires 
into the back of the unit and tightening the screws on the top of the unit with a small 
flat-head screwdriver.

 

Neutral

Earth

Live

Line

230 Vac

 

Tighten the screws 

with a small flat-head 

screwdriver.

3.  Push all power wires back into the electrical box and fasten the device to the 

electrical box with the provided screws.

NOTE:  

Use care when placing the device in the electrical box. Pinched wires 

may cause a short circuit.

 

4.  Attach the faceplate (not supplied).
5.  Ensure that all buttons, including the program button, actuate without sticking.
6.  Restore power at the circuit breaker.

Multigang Installation

In multigang installations, several devices are grouped horizontally or vertically in one 
electrical box. When ganging vertically the devices snap together by sliding the bottom of 
the upper device into the top of the lower device. This allows the devices to be mounted 
closer together.
For a smooth appearance, one-piece multigang faceplates (not included) can be installed.

NOTE:  

When devices are ganged in a horizontal position, the devices do not interlock.

NOTE:  

When installing into a multigang box, do not fully tighten devices to box until 

the faceplate has been aligned.