NOTE:
Since the plug on the power supply cord is used to disconnect power from
the unit, the socket-outlet should be installed near the equipment and shall be easily
accessible.
Hookup Connections for CNRACKX-DP
TO SERIAL
PORT ON PC
(PARALLEL DB9
CONNECTOR ALSO
ON CNRACKX-DP
FRONT PANEL)
OPTIONAL ETHERNET
EXPANSION CARDS
TO ETHERNET OR
LOCAL AREA NETWORK
TO OR FROM
ANY STS
OR CRESNET
NETWORK DEVICES
C
R
E
S
N
E
T
LAN
DPA
PROCESSOR
CONTROL
CNXCPU
G
Y
24
Z
CRESTRON
PWR
NET
C
R
E
S
N
E
T
LAN
DPA
PROCESSOR
CONTROL
CNXCPU
G
Y
24
Z
CRESTRON
PWR
NET
COM
P
U
T
E
R
CO
M
P
UT
ER
24VDC FROM
ONE CNPWS-75
(OR OTHER NET-
WORK DEVICES)
Programming the LCD Display
NOTE:
The following description assumes that the reader has some knowledge of
SIMPL Windows. If not, please refer to the extensive help information provided with
the software.
SIMPL (Symbol Intensive Master Programming Language) is an easy-to-use
programming language that is completely integrated and compatible with all
Crestron system hardware. The objects that are used in SIMPL are called symbols.
SIMPL Windows offers drag and drop functionality in a familiar Windows®
environment.
SIMPL Windows is Crestron Electronics development environment for
programming Crestron control systems. It provides a well-designed graphical
Operations Guide - DOC. 8151
CNX Dual Processor Modular Control System: CNRACKX-DP
•