CNX Dual Processor Modular Control System
Crestron
CNRACKX-DP
4. After a file is selected, the Update Control System dialog box, as
shown below, will query the CNRACKX-DP to determine what
versions of the Operating system, Monitor ROM, and TCP/IP Stack are
currently running.
Example Update Control System Dialog Box
5. If the CNRACKX-DP does not have optional Ethernet
Expansion Cards, uncheck the TCP/IP Stack option to transfer faster
(transferring the stack will not cause any problems). Otherwise, send all
of the checked components. To start the transfer, click the
Send
button.
The transfer dialog will inform you of the progress in updating the
selected components.
6. As a result of the update, a dialog box similar to below may open and
the SIMPL program (and possibly SIMPL+ modules) must be cleared.
Continue with transfer? Selection Box
7. Upload the SIMPL program and SIMPL+ modules after the transfer is
complete.
8. If both processors have not been updated, refer to the note at the
beginning of this procedure, electronically switch active processors,
and repeat this procedure.
32
•
CNX Dual Processor Modular Control System: CNRACKX-DP
Operations Guide - DOC. 8151