Test the Shade Travel
Test the travel of the shade fabric to ensure that it does not come in
contact with building materials and that the upper and lower shade limits
are properly set.
WARNING:
Care has been taken to ensure that the shade is properly
balanced. Prior to initial operation, confirm that the brackets are
adjusted so that the shade hangs level and plumb. Upon startup, run the
shade all the way down and check for plumb. Observe the shade closely
as it rolls up. If the shade begins to telescope, stop immediately and take
the appropriate action to ensure the shade tracks properly. To prevent
damage to the fabric from telescoping, do not leave the shade
unattended during the first few cycles of operation. Failure to follow
these instructions may result in damage to the edge of the fabric, which
is not covered by the warranty.
NOTE:
For Crestron Horizontal Sheers, the lower limit is defined as the
point before the hem bar tilts.
To test the lower limit:
1. Using the DN button, lower the shade until it reaches its lower limit.
Stop and adjust the mounting brackets if the fabric contacts any
building materials.
2. Verify that the shade stops at the desired lower limit. If the shade does
not travel to the desired lower limit, adjust the shade limits. For details,
refer to
Set the Shade Limits
.
To test the upper limit:
1. Using the UP button, raise the shade until it reaches its upper limit.
Stop and adjust the mounting brackets if the fabric contacts any
building materials.
2. Verify that the shade stops at the desired upper limit. If the shade does
not travel to the desired upper limit, adjust the shade limits. For
details, refer to
Set the Shade Limits
.
Set the Shade Limits
If necessary, set the lower and upper shade limits. If the shade limits are
not set, the red LED flashes three times, pauses for 1 second, flashes
once, pauses for 5 seconds, and then repeats this code until the limits are
set.
NOTES:
l
Limit Setup mode exits after 8 seconds of inactivity.
l
If a limit is not set after the upper or lower limit is saved, the motor
automatically enters Limit Setup mode for the opposite limit. This
typically occurs after the motor direction has been reversed and both
limits are erased.
l
For Crestron Horizontal Sheers, the lower limit is defined as the point
before the hem bar tilts.
Set the lower limit for the shade:
1. Press and hold the SET button for 4 seconds to enter Limit
Setup mode. The LED alternates between amber and green.
2. Press and release the DN button to begin lower limit setup. The green
LED flashes.
3. Use the UP and DN buttons to set the shade to its desired position.
4. Press and hold SET for 4 seconds. The LED turns solid red to confirm
that the lower limit was successfully set.
Set the upper limit for the shade:
1. Press and hold SET for 4 seconds to enter Limit Setup mode. The LED
alternates between amber and green.
2. Press and release the UP button to begin upper limit setup. The amber
LED flashes.
3. Use the UP and DN buttons to set the shade to its desired position.
4. Press and hold SET for 4 seconds. The LED turns solid red to confirm
that the upper limit was successfully set.
11
CS-SHADE-ROLLER-BATT
Quick Start
Shade Motor and Hardware for CS-SHADE-ROLLER-BATT with CSA-DECOR3 Brackets