Wall Plate DigitalMedia™ CAT Transmitters
Crestron
DM-TX-200-2G/400-3G
Installation
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications.
To install the DM-TX-200-2G or DM-TX-400-3G, the following tools and
accessories are required:
•
DM-CBL DigitalMedia Cable (sold separately). Refer to “Network Wiring”
on page 16.
•
Phillips screwdriver (not supplied)
•
Adjustable wrench (not supplied)
•
Miniature flat head screwdriver (not supplied)
•
#06-32 x 3/4" oval head slotted screws (included)
•
Decorative style faceplate (not supplied)
An extra-deep electrical box is recommended (2 1/2 inches (64 mm) deep minimum).
It is assumed that the required cable has been fed through an installed 2-gang or
3-gang electrical box (not supplied), and wiring has been verified.
1.
Confirm that DMNet system power is OFF.
2.
Strip 3 3/4 inches (95 mm) of the DigitalMedia Cable to expose the three
inner cables.
3.
Strip the outer jacket of the blue “D” cable 2 1/2 inches (64 mm) from end.
Gather and twist the wire braid. Refer to the following illustration.
“D” Cable (Stripping the Outer Jacket)
4.
Trim foil shield to 1/2 inch (13 mm).
5.
Remove the white neoprene sheath and separate the twisted pairs to expose
the spline. Cut the spline so it is near flush with the foil shield as shown in
the following illustration. Return twisted pairs to original position.
18
•
Wall Plate DigitalMedia™ CAT Transmitters: DM-TX-200-2G/400-3G Operations & Installation Guide – DOC. 6949B
Summary of Contents for DigitalMedia DM-TX-200-2G