Wall Plate DigitalMedia™ CAT Transmitters
Crestron
DM-TX-200-2G/400-3G
IP Configuration
If the DM-TX-200-2G or DM-TX-400-3G is used in a standalone configuration (i.e.,
without a DM switcher), use Crestron Toolbox to create the IP table entry for the
DM-TX-200-2G or DM-TX-400-3G.
NOTE:
If the DM-TX-200-2G or DM-TX-400-3G is connected directly to a DM
switcher, the IP table entry for the DM-TX-200-2G or DM-TX-400-3G is created
automatically.
1.
Use the Device Discovery Tool in Crestron Toolbox to find the IP address
of the DM-TX-200-2G or DM-TX-400-3G. Then, display the “System
Info” window (click the
icon) and select the DM-TX-200-2G or
DM-TX-400-3G entry from the Address Book.
2.
Select
Functions
|
IP Table Setup
.
3.
Add, modify or delete entries in the IP table. The DM-TX-200-2G or
DM-TX-400-3G can have only one IP table entry.
4.
A defined IP table can be saved to a file or sent to the device.
DMTool
In the Crestron Toolbox Address Book, select the DM-TX-200-2G or
DM-TX-400-3G. Then use the DMTool to configure EDID, HDCP or to
troubleshoot AV on the DM-TX-200-2G or DM-TX-400-3G. Refer to the help file
for additional information.
DMTool
DMTool
32
•
Wall Plate DigitalMedia™ CAT Transmitters: DM-TX-200-2G/400-3G Operations & Installation Guide – DOC. 6949B
Summary of Contents for DigitalMedia DM-TX-200-2G
Page 4: ......