16
•
DM-NVX-36x(C) Encoders/Decoders
Product Manual – DOC. 8879C
Settings Tab - System Setup, Point-to-Point Control
Using SIMPL Windows
Using the top-level programming slot for the DM-NVX-36x(C) device, set the
<PointToPointMode> analog input join to the desired value. For additional information,
refer to the SIMPL Windows help file.
Stream Statistics
Statistics can be displayed to indicate the number of packets received or transmitted,
the number of dropped packets, and the bit rate of the received stream. To enable or
disable or to reset stream statistics, use the web interface or SIMPL Windows as
discussed in the following sections.
Using the Web Interface
To enable, disable, or reset stream statistics:
1.
Click the Settings tab and then click Stream.
2.
In the Advanced section:
•
To enable or disable Statistics, set the Statistics toggle switch in the On
(right) or Off (left) position, respectively. The default setting is in the Off
(left) position.
•
To reset statistics, click Reset Statistics.
For additional information, refer to the online help of the web interface.