eServer™
File System Commands
These commands (
dir
,
del
,
xputfile
,
free
,
initialize
, and
type
) are available for
executing file system commands. There is no need to use these commands via the
setup menus since they are duplicated in Crestron software tools.
SIMPL+ Commands
These commands (
forth
,
newSIMPL
,
pause
, and
resume
) are available for executing
SIMPL+ commands. There is no need to use these commands via the setup menus
since they are duplicated in SIMPL+.
Programming with SIMPL™ Windows
To implement the eServer in a Crestron CNX control system, use a SIMPL Windows
program (drop the CEN-OEM definition from the Ethernet Devices folder in
Configuration Manager). The eServer definition can be found in the Ethernet Control
Modules folder in the
Device Library
. The CEN-OEM, like any other device that is
controlled via Ethernet from a Crestron control system, gets an IP ID and an entry in
the IP Table of the control system. Refer to "ip_adr" on page 15 for setting the CEN-
OEM IP ID. For details about the IP Table, refer to "Add_master" on page 14.
Use of the CEN-OEM symbol is necessary to incorporate the eServer functionality in
a Crestron CNX control system. The SIMPL+ program or module that complements
the SIMPL Windows program with eServer symbol is necessary to program the
eServer itself.
CEN-OEM Symbol
The interface to the CEN-OEM symbol in Program Manager looks like the symbol
for a touchpanel. There are digital input/output lists, analog input/output lists, and
serial input/output lists. The figure after this paragraph illustrates the CEN-OEM
digital symbol as it appears in the
Detail View
of Program Manager.
CEN-OEM Symbol
SIMPL+ Interface
The following table shows how the SIMPL+ program inside the CEN-OEM
interprets data routed into and out of the symbol.
20
•
Ethernet OEM Module: eServer™
Operations Guide - DOC. 8148