background image

The Crestron®

FT2-700-MECH

,

FT2-700-MECH-PTL

,

FT2-700-MECH-AC

and the

FT2-700-MECH-ACUSB

FlipTop™ cable

management systems install into a table or other horizontal surface to
provide modular tabletop connectivity for users. The FT2-700-MECH
series feature a one touch lid that retracts fully and disappears with the
tap of a button. When the lid is retracted, 12 module slots are arranged in
two rows of six. The flexible modular design may also be customized with
an assortment of Crestron accessories. For more information about the
accessories, please visit

www.crestron.com/Crestron-FlipTops

.

The FT2-700-MECH-PTL offers an alternative pass-through lid style
which allows cables to be fully extended while the lid is closed.

The FT2-700-MECH-AC includes an FT2A-PWR-US-1-BASIC AC power
outlet module. Similarly, the FT2-700-MECH-ACUSB includes an
FT2A-PWR-US-1-BASIC and an FT2A-CHGR-USBA-BASIC USB rapid
charging module.

The FT2-700-MECH, FT2-700-MECH-PTL, FT2-700-MECH-AC, and the
FT2-700-MECH-ACUSB are all functionally similar. For simplicity within
this document, they are all referred to as the "FT2-700 assembly."

In the Box

1

FT2-700-MECH, FlipTop™ FT2 Series, 700 Size, Mechanical

Additional Items

3

Bars, Locking, with Screws (P/N 4528906)

4

Module, Blank Plate (P/N 2049602)

8

Module, Pass-Through Cable (P/N 4526880)

4

Spacer, Plastic, FT2-700 (P/N 2050568)

1

Template, Cutout (P/N 4527491)

FT2-700-MECH-AL, FT2-700-MECH-AC-A, and
FT2-700-MECH-ACUSB-A Only

1

Bezel, FT2-700, Alloy (P/N 4529321)

FT2-700-MECH-PTL-AL Only

1

Bezel, FT2-700, Pass-Through Lid, Alloy (P/N 4531563)

FT2-700-MECH-PTL-B Only

1

Bezel, FT2-700, Pass-Through Lid, Black (P/N 4531562)

FT2-700-MECH-B, FT2-700-MECH-AC-B, and
FT2-700-MECH-ACUSB-B Only

1

Bezel, FT2-700, Black (P/N 4529320)

FT2-700-MECH-AC-A, FT2-700-MECH-AC-B,
FT2-700-MECH-ACUSB-A, and FT2-700-MECH-ACUSB-B Only

1

FT2A-PWR-US-1-BASIC, AC Power Outlet Module
(P/N 6510522)

1

FT2-700-MECH Series

Quick Start

FlipTop™ FT2 Series, 700 Size, Mechanical

Summary of Contents for FlipTop FT2-700-MECH

Page 1: ...n FT2A CHGR USBA BASIC USB rapid charging module The FT2 700 MECH FT2 700 MECH PTL FT2 700 MECH AC and the FT2 700 MECH ACUSB are all functionally similar For simplicity within this document they are all referred to as the FT2 700 assembly In the Box 1 FT2 700 MECH FlipTop FT2 Series 700 Size Mechanical Additional Items 3 Bars Locking with Screws P N 4528906 4 Module Blank Plate P N 2049602 8 Modu...

Page 2: ...s cable retractors for above the table cable pull out lengths For a new mounting follow sections Cut the Mounting Hole and Secure the FlipTop Assembly To use the mounting hole of an existing FT 600 FlipTop assembly follow sections Replace the FT 600 FlipTop Assembly and Secure the FlipTop Assembly Cut the Mounting Hole A saw tracing utensil and the included cutout template are required to cut the ...

Page 3: ...cure the FlipTop Assembly To secure the FT2 700 assembly to the table surface 1 Ensure that all four swiveling dogs are tucked inside of the FT2 700 assembly and then insert the FT2 700 assembly into the mounting hole until the top lip is flush with the table surface 2 Carefully tighten the four swiveling dogs in each corner of the FlipTop assembly clockwise until the FT2 700 assembly is secured i...

Page 4: ...of a module row l Dress all cables after installing each module Install the Pass Through Cable Module The FT2A PLT PT pass through modules enable FT2 CBL PT pass through cables and other types of interface cables to be installed within the FT2 700 assembly Each FT2A PLT PT cable module is packaged with one nylon grommet and one cable plate One empty module slot in the FT2 700 assembly and one FT2 ...

Page 5: ...ables The grommet is recommended to use with cables that are 10 mm or thinner 1 Open the grommet 2 Insert a cable into the grommet with the connector facing up toward the end user 3 Press the grommet back together to secure the cable inside 4 Push the grommet and cable through the hole in the cable plate 5 Insert the cable plate into one of the three slots in the pass through module Choose the app...

Page 6: ...ows A keystone plate sold separately module allows for cables terminated with standard keystone jacks to be installed in the FT2 700 assembly The blank and keystone modules each require one empty module slot for installation Blank and Keystone Plate Modules To install a blank or keystone plate module into the FT2 700 assembly l Slide the blank plate module down into the appropriate module slot Use...

Page 7: ...west possible setting hand tighten the locking bar screws until the locking bars are secured to the FT2 700 assembly CAUTION Do not overtighten the locking bar screws Install the Bezel Place the bezel onto the FT2 700 assembly so that the retractable lid fits inside the bezel opening The bezel is held in place using magnets 7 FT2 700 MECH Series Quick Start FlipTop FT2 Series 700 Size Mechanical ...

Page 8: ...lose the lid by lifting it vertically and returning it over the FlipTop assembly Visit the Product Page Scan the QR code to visit the product page FT2 700 MECH www crestron com model 6508395 FT2 700 MECH PTL www crestron com model 6511412 FT2 700 MECH AC www crestron com model 6510769 FT2 700 MECH ACUSB www crestron com model 6510771 8 FT2 700 MECH Series Quick Start FlipTop FT2 Series 700 Size Me...

Page 9: ...arranty can be found at www crestron com warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source software For specific information visit www crestron com opensource Crestron the Crestron logo and FlipTop are either trademarks or registered trademarks of Crestron Electronics Inc in the United States and or...

Reviews: