36 • HD-RX-4K-x10-C-E(-SW4)
Web Interface Configuration Guide — Doc. 9211A
2. (Applicable only when Send Command is set to CEC ->Custom or RS232) Do the following:
a. Select the HEX (default value) or ASCII from the Command Format drop-down list
to specify whether the format of the command will be hexadecimal (HEX) or ASCII.
b. In the Command String text entry field, enter the appropriate command string
based on display capabilities.
When the HEX command format is selected, the Command String must be entered
as pairs of characters separated by a space. Valid characters are 0-9, a-f, and A-F.
A command string example is shown below:
58 00 0D 0A
c. In the Command Terminator drop-down list, select one of the following terminators
to append to the command:
l
None (specifies no terminator).
l
CR (carriage return).
l
LF (line feed).
l
CR LF (carriage return followed by a line feed).
3. If desired, enable Input Control by toggling the Input Control switch to Yes to control
which HDMI input on the display is to be used to turn on the display. The default setting is
No.
4. (Applicable only when Input Control is set to Yes) Do the following:
a. Set Delay to the amount of time in seconds that must pass before input control
commands can be sent to the display.
b. Select the HEX (default value) or ASCII from the Command Format drop-down list
to specify whether the format of the command will be hexadecimal (HEX) or ASCII.
c. In the Command String text entry field, enter the command in hexadecimal or ASCII
format.
When the HEX command format is selected, the Command String must be entered
as pairs of characters separated by a space. Valid characters are 0-9, a-f, and A-F.
A command string example is shown below:
58 00 0D 0A