background image

6.4 Inch Tilt Touchpanel 

 

Crestron Isys

®

 

TPS-3000

 

 

The required wire gauge should be chosen such that the resistance value is less than 
the value calculated in the resistance equation. Refer to the following table. 

Wire Gauge Values 

RESISTANCE WIRE 

GAUGE 

4 16 

18 

10 20 
15 

22 

13 Doubled 

CAT5 

8.7 

Tripled CAT5 

NOTE:

  All Cresnet wiring must consist of two twisted pairs. One twisted pair is the 

+24V conductor and the GND conductor, and the other twisted pair is the Y 
conductor and the Z conductor.  

NOTE:  

When daisy-chaining Cresnet units, strip the ends of the wires carefully to 

avoid nicking the conductors. Twist together the ends of the wires that share a pin on 
the network connector, and tin the twisted connection. Apply solder only to the ends 
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle. 
Insert the tinned connection into the Cresnet connector and tighten the retaining 
screw. Repeat the procedure for the other three conductors. 

NOTE:

  For additional general information on video connections over CAT5, refer 

to the latest version of the Crestron CAT5 Wiring Reference Guide (Doc. 6137) 
which is available from Crestron website. 

NOTE:  

For larger networks (i.e., greater than 28 network devices), it may be 

necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality 
throughout the network. Also, for networks with lengthy cable runs or varying types 
of network devices, it may be desirable to add a hub/repeater after only 20 network 
devices.  

Identity Code 

Every equipment and user interface within the network requires a unique Cresnet 
Identity code (Net ID). These codes are assigned a two-digit hexadecimal number 
from 03 to FE. Refer to "Interface Menu” on page 12 for instructions on setting the 
unit's Net ID. The Net ID of the unit must match the Net ID specified in the SIMPL 
Windows program. Refer to “Setting the Net ID in Device Settings” on page 24 for 
an example of a SIMPL Windows program. 

Configuring the Touchpanel 

NOTE:

 The only connection required to configure the touchpanel is power (supplied 

via Cresnet). Refer to “Hardware Hookup” on page 17 for details. 

To configure the unit, it may be necessary to access a series of setup screens prior to 
viewing run-time screens that are loaded into the touchpanel for normal operation. 
The MAIN MENU for configuring the touchpanel appears when a finger is held to 

10  

  6.4 Inch Tilt Touchpanel: Crestron Isys

®

 TPS-3000 

Operations Guide – DOC. 6076A 

Summary of Contents for Isys TPS-3000

Page 1: ...Crestron Isys TPS 3000 6 4 Inch Tilt Touchpanel Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...are Requirements for the PC 22 Programming with Crestron System Builder 22 Programming with SIMPL Windows 23 Programming with VisionTools Pro e 27 Reserved Join Numbers 28 MultiByte International Char...

Page 4: ......

Page 5: ...99 serial signals Built in microphone and two speakers half duplex intercom capable Stores and plays back WAV sound files Stereo headphone jack Fast graphics performance import photographs drawings an...

Page 6: ...s thus eliminating most distortion at the speakers For quiet audio signals the gain is not reduced When Dynamic range compression is turned off default the audio amplifier gain remains fixed for all s...

Page 7: ...t in WAV file 8bit 8kHz mono PCM type key click capability Stereo headphone mini phone jack on rear of unit Speaker amplification 2 Watts per channel Microphone 600 Ohms balanced and 300 Ohms unbalanc...

Page 8: ...des the HBK 3000 hatchback 1 The latest versions can be obtained from the Downloads Software Updates section of the Crestron website Refer to NOTE after last footnote 2 Crestron 2 Series control syste...

Page 9: ...aragraph This touchpanel is designed for placement on a tabletop or other flat surface It possesses a hinged base which can tilt from 30 to 80 degrees All audio RS 232 video network and power connecti...

Page 10: ...00 Back View with HBK 3000 Hatchback Option Sold Separately Optional Hatchback HBK 3000 Optional SMK 3000 Rotating Base Accessory Sold Separately and Includes HBK 3000 6 6 4 Inch Tilt Touchpanel Crest...

Page 11: ...Isys TPS 3000 6 4 Inch Tilt Touchpanel Physical View of the TPS 3000 Touchpanel Front Physical View of the TPS 3000 Touchpanel Side Operations Guide DOC 6076A 6 4 Inch Tilt Touchpanel Crestron Isys TP...

Page 12: ...ilt Touchpanel Crestron Isys TPS 3000 Physical View of the TPS 3000 Touchpanel Bottom Physical Views of the TPS 3000 Touchpanel Back 8 6 4 Inch Tilt Touchpanel Crestron Isys TPS 3000 Operations Guide...

Page 13: ...ulator to help calculate how much power is needed for the system http www crestron com calculators CAUTION Use only Crestron power supplies for Crestron equipment Failure to do so could cause equipmen...

Page 14: ...6137 which is available from Crestron website NOTE For larger networks i e greater than 28 network devices it may be necessary to add a Cresnet Hub Repeater CNXHUB to maintain signal quality througho...

Page 15: ...RATION MENU offers the choice to initiate calibration with the Perform Calibration button or return to the previous screen with the Return button Choose an option by touching the correct button If you...

Page 16: ...communication will not occur To set communication parameters select the Interface button located on the SETUP MENU and display the INTERFACE MENU shown below The Cresnet network identity number CRESN...

Page 17: ...AV Off disables this feature Adjust the volume with the UP and DOWN buttons Select the Play WAV File to sample and adjust the volume as a pre loaded WAV file plays Line 88 On Line Enable line level au...

Page 18: ...ases video image brightness Contrast UP button increases video image contrast DOWN button decreases video image contrast Saturation UP button increases video image saturation DOWN button decreases vid...

Page 19: ...tting and return to the SETUP MENU TIMEOUT SETTINGS RS 232 Menu The touchpanel allows for one of four RS 232 communication modes console i e loading programs control i e non Crestron device touch outp...

Page 20: ...the Return button on the SCREEN SETTINGS display The current screen brightness setting is shown on this page The screen brightness is factory set to 100 Changes to the brightness level are performed o...

Page 21: ...CAUTION Do not apply excessive pressure to the touchscreen display during handling Doing so can crack the screen and damage the touchpanel The TPS 3000 touchpanel has rubber pads on the underside of i...

Page 22: ...ph AUDIO Pinouts PIN DESIGNATION DESCRIPTION 1 L Left Input Positive 2 L Left Input Negative 3 GND Ground 4 R Right Input Positive 5 R Right Input Negative 6 S Shield 7 M Mic Output Positive 8 M Mic O...

Page 23: ...C Chrominance Positive 4 C Chrominance Negative 5 Y Data Network 6 Z Data Network 7 Y Luminance Positive Composite 8 Y Luminance Negative Composite 9 GND Ground Network 10 24V Power Network Pin 1 Pin...

Page 24: ...n Cleaning Keep the surface of the touchscreen free of dirt dust or other materials that could degrade optical properties Long term contact with abrasive materials can scratch the surface which may de...

Page 25: ...amming for a base system including all touchpanel screens and the control system program The program output of SystemBuilder is a SIMPL Windows program with much of the functionality encapsulated in m...

Page 26: ...gram There are digital join numbers that carry out some predetermined function a logical high or low analog join numbers for displaying incremental values sliders gauges and bar graphs and serial join...

Page 27: ...nfigure program test and monitor a Crestron control system SIMPL Windows offers drag and drop functionality in a familiar Windows environment This section describes a sample SIMPL Windows program that...

Page 28: ...touchpanel in Slot 9 with a default Net ID of 03 as shown in the following illustration C2Net Device Slot 9 Setting the Net ID in Device Settings Double click the TPS 3000 icon in the upper pane to op...

Page 29: ...ystem by assigning signals to symbols The following diagram shows the TPS 3000 symbol in the SIMPL Windows Programming Manager Detail View of the TPS 3000 in SIMPL Windows Programming Manager NOTE Pin...

Page 30: ...ey too contain 16 bits of information However whereas the value of an analog signal is used directly to control volume or temperature for instance the value of the serial signal is used as a pointer t...

Page 31: ...Search for TPS 3000 zip Programming with VisionTools Pro e VT Pro e a design and programming Windows based software permits the creation of unlimited control screen variations incorporating two and th...

Page 32: ...help file in VT Pro e to learn how to use its audio tool Sound Manager to attach WAV files to a touchpanel project Pre recorded WAV files for voice prompts and responses are available from Crestron T...

Page 33: ...NPUT OUTPUT 17101 Video Contrast INPUT OUTPUT 17102 Video Saturation INPUT OUTPUT 17103 Video Hue INPUT OUTPUT System Digital Reserved Join Numbers for TPS 3000 Touchpanels JOIN FUNCTION VALUE IN OUT...

Page 34: ...ic AGC On INPUT OUTPUT 17319 Audio Mic AGC Off INPUT OUTPUT 17321 Audio Defaults INPUT 17325 Audio Bass Increase INPUT 17326 Audio Bass Decrease INPUT 17327 Audio Treble Increase INPUT 17328 Audio Tre...

Page 35: ...ays the string but it is not dynamic Uploading and Upgrading NOTE Crestron recommends that you use the latest software and that each device contains the latest firmware to take advantage of the most r...

Page 36: ...ilable from the Downloads Product Manuals section of the Crestron website To prepare the TPS 3000 for uploading or upgrading through a control system refer to the following figure for a typical commun...

Page 37: ...gs alternatively depress Alt D to open the Port Settings window Setup Comunications Settings Command 4 Select RS 232 as the connection type Verify that an available COM port COM 1 is shown after this...

Page 38: ...w 3 Navigate to the SIMPL Window file smw and click Open 4 Select Project Transfer Program Upload via Crestron Viewport 1 Verify that the procedure for Communication Settings that begins on page 32 ha...

Page 39: ...Viewport The TPS 3000 touchpanel source file has the extension vtp A compiled VT Pro e file has the extension vtz Upload via VT Pro e 1 Start VT Pro e 2 Select File Open Project to view the Open wind...

Page 40: ...cted using the Browse command that project is added to the File Name drop down list This makes it convenient to recall projects without need to browse to a directory To delete the list click Clear His...

Page 41: ...e but as Crestron improves functions adds new features and extends the capabilities of its products firmware upgrades are posted To upgrade the firmware complete the following steps 1 Make sure that S...

Page 42: ...t Touchpanel Crestron Isys TPS 3000 Select Network ID Window Open Window 4 Browse to the csf file and click Open to begin the transfer 38 6 4 Inch Tilt Touchpanel Crestron Isys TPS 3000 Operations Gui...

Page 43: ...calibrated Enter SETUP MODE and recalibrate Incorrect network wiring Verify correct wiring to all connectors Touchpanel Cresnet ID is not set to match the Net ID in the SIMPL program Touch the screen...

Page 44: ...on website to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions ad...

Page 45: ...data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software...

Page 46: ...y 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its op...

Page 47: ...lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of th...

Page 48: ...Crestron Electronics Inc Operations Guide DOC 6076A 15 Volvo Drive Rockleigh NJ 07647 03 05 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: