Microphone Settings
Select the Microphone tab to view the available microphone settings.
Microphone Tab
The following microphone settings can be configured. These settings can also be modified by
editing the Room Designer file.
Microphone Device Settings
The Microphone Device Settings table is used to add the control IP addresses of each
microphone or automix device used within the camera switching system.
Microphone Device Settings Table
l
IP: Enter the control IP address of the microphone or automixer device. Do not enter the
Dante IP address of the device.
l
Used Channels: Enter the number of channels (or lobes) in use by the device.
l
Spare Channels: Enter the spare channels (or lobes) that are not in use by the device.
NOTE: The Spare Channels field is used to reserve additional camera presets in case
extra channels must be added to a device during or after configuration. For example, if
using a Shure MXA-910 microphone but not all 8 lobes are in use, it is recommended to
set 2 or 3 spare channels.
l
Model: Select the microphone or automixer device model from the drop-down menu:
o
ADECIA
o
Intellimix Room
o
MXA310/910
o
MXA920
o
MXC / MXCW
o
P300
o
Q-SYS
o
Tesira
o
TCC2
o
Taiden
Select Add Device to add additional devices to the table.