Crestron
MPC-M50
Media Presentation Controller
9.
Click the
icon and select
Firmware…
to open the “Firmware”
window, then click
Browse
.
10.
Find and select the correct firmware file (.CUZ or .zip) and click
Open
.
11.
In the “Firmware” window, click
Send
. You will see a “Confirmation”
window asking if you have selected the right file. Click
OK
and you will
see the “File Transfer” window.
12.
When file transfer is completed, a window asking you to re-connect
appears. Click
Okay
, then close the “Firmware” window and re-connect
using the normal Address Book entry.
Check Network Wiring
Use the Right Wire
In order to ensure optimum performance over the full range of your installation
topology, use Crestron Certified Wire only. Failure to do so may incur additional
charges if support is required to identify performance deficiencies because of using
improper wire.
Calculate Power
CAUTION:
Use only Crestron power supplies for Crestron equipment. Failure to
do so could cause equipment damage or void the Crestron warranty.
CAUTION:
Provide sufficient power to the system. Insufficient power can lead to
unpredictable results or damage to the equipment. Please use the Crestron Power
Calculator to help calculate how much power is needed for the system
(
When calculating the length of wire for a particular Cresnet run, the wire gauge and
the Cresnet power usage of each network unit to be connected must be taken into
consideration. Use Crestron Certified Wire only. If Cresnet units are to be daisy-
chained on the run, the Cresnet power usage of each network unit to be daisy-
chained must be added together to determine the Cresnet power usage of the entire
chain. If the unit is home-run from a Crestron system power supply network port, the
Cresnet power usage of that unit is the Cresnet power usage of the entire run. The
wire gauge and the Cresnet power usage of the run should be used in the following
equation to calculate the cable length value on the equation’s left side.
Cable Length Equation
L = Length of run (or chain) in feet
R = 6 Ohms (Crestron Certified Wire: 18 AWG (0.75 mm ))
or 1.6 Ohms (Cresnet HP: 12 AWG (4 mm ))
P = Cresnet power usage of entire run (or chain)
2
2
L <
40,000
R x P
Where:
Make sure the cable length value is less than the value calculated on the right side of
the equation. For example, a Cresnet run using 18 AWG Crestron Certified Wire and
drawing 20 watts should not have a length of run more than 333 feet (101 meters). If
Cresnet HP is used for the same run, its length could extend to 1250 feet (381
meters).
NOTE:
All Crestron certified Cresnet wiring must consist of two twisted pairs. One
twisted pair is the +24V conductor and the GND conductor and the other twisted
pair is the Y conductor and the Z conductor.
Operations & Installation Guide – DOC. 6814B
Media Presentation Controller: MPC-M50
•
25