background image

2-Way RF Wireless Touchpanel 

Crestron 

STX-1700C 

 

decrease the most significant digit by one, respectively (i.e., 1, 2, 3, …F). Refer to 
the latest revision of the STRFGWX Operation Guide (Doc. 5811) for more 
information on setting up the RF Channel for the RF gateway. 

 

NOTE:

  The 

RF TEST MENU 

button

 

should only be used under supervision from 

a Crestron customer service representative during telephone support.  

After the Cresnet ID, RF ID and RF Channel settings have been verified, touch the 

Return

 button at the bottom of the screen to save settings and display the SELECT 

INTERFACE screen. 

 
KEY CLICK SETUP 

 

 
 

Key Click Setup 

From the SETUP MENU, press the 

Key Click Enabled

 button to open KEY CLICK 

SETUP screen. (If the function is currently disabled, the button legend is “

Key Click 

Disabled

.”)  To enable an audible tone (beep) when the touchpanel buttons are 

pressed, select among the 

Short, Med, 

or 

Long 

KEY CLICK ENABLE/LEN 

buttons to set the duration of the tone. The touchpanel responds with a corresponding 
signal. To disable the feature, select 

Click Off

Use the KEY CLICK VOLUME 

UP

 and 

DOWN

 buttons to increase and decrease 

the volume of the signal. The area to the right of the buttons shows the relative 
volume from 0% to 100%, both as a numeric value and, for a quick visual reference, 
as an analog bar.  
Select the 

Return

 button to return to the SETUP MENU. 

SCREEN SETTINGS - 
BRIGHTNESS 

 

Brightness 

From the SETUP MENU, press the 

Brightness 

button to open the SCREEN 

SETTINGS – BRIGHTNESS screen. The 

UP

 and 

DOWN

 buttons increase and 

decrease screen brightness, respectively. The area to the right of the buttons shows 
the relative brightness from 0% to 100%. 
Select the 

Return

 button to return to the SETUP MENU. 

 
STARTUP PREFERENCE 

 

 

 
 

Startup Preference 

NOTE:

  This feature applies only to units with the optional pushbuttons installed. 

Refer to “Appendix B:  Installation of Optional Pushbuttons” for details. 

The Startup Preference option allows (when the touchpanel is off or in standby) the 
display to come on or stay off when a “quick” pushbutton is pressed. From the 
SETUP MENU, press the 

Startup Preference 

button to open the STARTUP 

PREFERENCE screen.  
When pressed, the 

DISPLAY ON FROM HARDKEY

 button toggles between 

ENABLED and DISABLED. With ENABLED selected, the display comes on when 
one of the “quick” pushbuttons is pressed. With DISABLED selected, the display 
stays off when a “quick” pushbutton is pressed (if touchpanel was off, it goes to 
standby).  The default is DISABLED. 
Select the 

Return

 button to return to the SETUP MENU. 

10  

  2-Way RF Wireless Touchpanel: STX-1700C  

Operations Guide - DOC. 6226A 

Summary of Contents for STX-1700C

Page 1: ...Crestron STX 1700C 2 Way RF Wireless Touchpanel Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Builder 13 Programming with SIMPL Windows 13 Programming with VT Pro e 18 Optional Pushbuttons 18 Reserved Join Numbers 18 Uploading and Upgrading 19 Communication Settings 20 Uploading a VT Pro e Pro...

Page 4: ......

Page 5: ...particular area or installation The location and the antenna position of the STRFGWX are important factors in the RF reception transmission The range of the touchpanel is also dependent on its placeme...

Page 6: ...to power the touchpanel Refer to the latest revisions of the documentation supplied with these items for descriptions and details Roaming Feature This feature allows an STX 1700C to extend its range...

Page 7: ...n 4 02 02S UPZ or later Acceptable file extensions 5 vtz csf projectname vtz compiled file STX1700C vx xxx x csf panel firmware STRFGWX firmware Version 2 4 1 2843 upg or later RF Specifications 2 Way...

Page 8: ...Transceiver 7 The weight listed is for the touchpanel and does not include the ST BTPN ST DSN or external power pack NOTE Crestron software and any files on the website are for Authorized Crestron dea...

Page 9: ...0 cm 4 24 in 10 76 cm 5 01 in 12 73 cm upload connector Cresnet Power connector The underside of the unit contains the battery compartment that holds one ST BTPN Contacts for the ST DSN are through th...

Page 10: ...n If this equipment does cause harmful interference to radio or television reception which can determined by turning the equipment off and on the user is encouraged to try to correct the interference...

Page 11: ...el firmware RF ID Every STX 1700C touchpanel communicating with a Cresnet control system via a STRFGWX requires a unique RF ID to secure RF communications There are 15 useable codes for multiple touch...

Page 12: ...offers the choice to initiate calibration with the Perform Calibration button or return to the previous screen with the Return button Choose an option by touching the appropriate button If you need to...

Page 13: ...spectively Use these screens to set the Cresnet network identity CRESNET ID and the RF ID numbers Cresnet Interface Menu CRESNET INTERFACE MENU 03 RF SETUP 1 CRESNET ID is a two digit hexadecimal numb...

Page 14: ...relative volume from 0 to 100 both as a numeric value and for a quick visual reference as an analog bar Select the Return button to return to the SETUP MENU SCREEN SETTINGS BRIGHTNESS Brightness From...

Page 15: ...d in minutes The default POWER DOWN timeout is 30 minutes Adjusts in one minute increments from 1 to 10 in ten minute increments from 20 120 NOTE Power Down Timeout should be set low to maximize batte...

Page 16: ...r account You can create a program that allows you to set up the STX 1700C to operate a Crestron control system using the Crestron programming tools Crestron SystemBuilder and SIMPL Windows These tool...

Page 17: ...tools behind the scenes enabling you to easily create robust systems Programming with SIMPL Windows NOTE The following assumes that the reader has knowledge of SIMPL Windows If not refer to the extens...

Page 18: ...RF folder of the Device Library and drop it in the upper pane of the System Views The System Views upper pane displays the STRFGWX device icon below the PRO2 graphic Drag the STX 1700C from the Touchp...

Page 19: ...low For more information on setting the RF IR ID refer to RF Setup screen shown on page 9 Touchpanel Device Settings Window STX 1700 Symbol in Programming Manager Programming Manager is where programm...

Page 20: ...analog signals can vary continuously in value in the same manner as a parameter such as volume temperature or pressure Analog signals contain 16 bits of information which means that this type of signa...

Page 21: ...ff line during polling by the control system In wireless mode Sleep Wake Manager suspends and restores operation of the touchpanel For additional information about Device Extenders refer to the latest...

Page 22: ...Assignment If the optional ten hard pushbuttons are installed you can use these buttons to access any frequently used commands refer to Appendix B Installation of Optional Pushbuttons Each button has...

Page 23: ...to perform the function O indicates feedback to the display all actions are local to the touchpanel no information is transmitted Analog Reserved Join Numbers for STX 1700C JOIN NUMBER FUNCTION VALUE...

Page 24: ...ions in the Viewport menus Therefore for its effectiveness as a support and diagnostic tool the Crestron Viewport may be preferred over development tools when uploading programs and projects The follo...

Page 25: ...r either configuration refer to the Programming Cable Specifications diagram after these notes NOTE An adapter such as a CN RJ11 sold separately is required when using the RJ 11 cable NOTE The RJ 11 p...

Page 26: ...ctor labeled NET on the control system 4 Attach the appropriate external power pack or equivalent to touchpanel and plug into outlet At the PC make sure that no programs accessing the COM port of the...

Page 27: ...k the OK button to save the settings and close the window NOTE If problems occur when transferring any Cresnet file touchpanel project firmware lower the port speed baud rate to 38400 to match the Cre...

Page 28: ...File Transfer Send Touchpanel alternatively depress Alt T from the Viewport menu Select Send Touchpanel 3 As shown below select the Net ID of the STX 1700C and then click OK The Touchpanel Transfer w...

Page 29: ...e for the latest version of firmware Not every product has a firmware upgrade but as Crestron improves functions adds new features and extends the capabilities of its products firmware upgrades are po...

Page 30: ...w 4 As shown below select the firmware CSF file and click Open The transfer will complete automatically Select CSF File 5 Disconnect the programming cable and the external power pack from the touchpan...

Page 31: ...s power supplied to it either battery or power pack Communications error between PC and control system Verify upload preferences is set to the COM port being used to communicate to the control system...

Page 32: ...f the STRFGWX Refer to RF Setup on page 9 for details and RF ID parameters assigned in the program Touchpanel screen changes without touching the screen Touchpanel went out and then in range while con...

Page 33: ...ce team by calling the Crestron corporate headquarters at 1 888 CRESTRON 1 888 273 7876 For assistance in your local time zone refer to the Crestron website http www crestron com for a listing of Cres...

Page 34: ...on for any RF transceiver is obtained by installing the gateway transceiver in an open area or shelf with a clear line of sight no obstructions between gateway and receiver Crestron recommends that th...

Page 35: ...p of gateway Antenna Building Vertical Orientation Antenna Front of gateway Building RF GATEWAY 2 WAY PWR NET Rx SIG RF Tx STRFGWX ANTENNA CRESTRON Right Angle Orientation Antenna Building Top of gate...

Page 36: ...the bezel from the base 3 Assemble the supplied membrane switches to the pushbutton sets Notice that the pushbutton sets fit snugly on the membrane switches Refer to the following Notes 4 Put the ass...

Page 37: ...ands data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Sof...

Page 38: ...nety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its...

Page 39: ...t lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of t...

Page 40: ...Crestron Electronics Inc Operations Guide DOC 6226A 15 Volvo Drive Rockleigh NJ 07647 12 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: