Drywall Cutout Template and Dimensions (supplied with WMKT-12L only), 2 of 2
12.00 in
(305 mm)
.188 TYP
1 1/16 in
(27 mm)
11 1/4 in
(286 mm)
11.00 in
(279 mm)
1/8 in
(3 mm)
2 5/16 in
(58 mm)
13 5/8 in
(346 mm)
12 7/8 in
(327 mm)
10 3/4 in
(274 mm)
6 1/4 in
(158 mm)
Installation
This section provides an installation procedure for each Trim Ring Mount Kit. The
“TMK-12L Procedure” starts below and the “WMKT-12L Procedure” starts on page
6. Be sure to review each procedure before starting.
TMK-12L Procedure
This section provides the necessary steps for the assembly of the TMK-12L with
either the BB-12L or PMK-12L. It is assumed that the BB-12L or PMK-12L has
been secured to the stud according to the instructions in the latest revisions of their
Installation Guides (Doc. 6357 and Doc. 6358 respectively). It is also assumed that
drywall is in place and a cutout is made in the drywall along the inside of the
mounting plate for touchpanel installation.
Complete the steps in the order provided. The only tool required and not supplied is
a level.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity
above and below the touchpanel for heat dissipation.
NOTE:
When installing into the PMK-12L, verify that the 18 AWG bus wire
securing the cables for the touchpanel remains attached.