Crestron
TPMC-4SMD
4.3” Designer Touch Screen
Setup
Network Wiring
When wiring the Ethernet network, consider the following:
•
Use Crestron Certified Wire.
•
Use Crestron power supplies for Crestron equipment.
•
Provide sufficient power to the system.
CAUTION:
Insufficient power can lead to unpredictable results or damage
to the equipment. Please use the Crestron Power Calculator to help calculate
how much power is needed for the system (
Unlike other Crestron network devices, the TPMC-4SMD does not use Cresnet
for
communications between the device and the control system. The TPMC-4SMD
requires the use of a high-speed Ethernet connection for control system
communications.
For general information on connecting Ethernet devices in a Crestron system, refer to
the Crestron e-Control
Reference Guide (Doc. 6052) at
Identity Code
NOTE:
The latest software can be downloaded from the Crestron Web site
The IP ID is set within the TPMC-4SMD’s IP table using Crestron Toolbox™. For
information on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs
of multiple TPMC-4SMD devices in the same system must be unique.
When setting the IP ID, consider the following:
•
The IP ID of each unit must match an IP ID specified in the Crestron
Studio™ or SIMPL Windows program.
•
Each device using IP to communicate with a control system must have a
unique IP ID.
Configuring the Touch Screen
NOTE:
The only connection required to configure the touch screen is power. Refer
to “Hardware Hookup” on page 27 for details.
NOTE:
The TPMC-4SMD can take up to 45 seconds to boot to a display after
initial power up.
The setup screens allow basic configuration procedures prior to regular operation of
the touch screen. To enter the setup screens, touch the panel while applying power to
the unit. The setup screens can also be entered by pressing the top four push buttons
Operations & Installation Guide – DOC. 7027E
4.3” Designer Touch Screen: TPMC-4SMD
•
11