background image

 

 

Crestron 

TPS-4500IMW

 

Wall-Mounted Interface Module 
Operations Guide 

 

 

Summary of Contents for TPS-4500IMW

Page 1: ...Crestron TPS 4500IMW Wall Mounted Interface Module Operations Guide...

Page 2: ...This document was prepared and written by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON...

Page 3: ...Description 1 Physical Description 1 I O Ports 1 Leading Specifications 4 Setup 4 Network Wiring 4 Hardware Hookup 5 Problem Solving 9 Troubleshooting 9 Further Inquiries 9 Future Updates 10 Return a...

Page 4: ......

Page 5: ...with a decora wallplate not supplied so that the unit blends into any setting Physical Description The TPS 4500IMW shown on the next page is an option can be purchased separately The unit mounts into...

Page 6: ...l Views of the TPS 4500IMW Front with Insert Plate Side and Back 2 505 in 6 363 cm CRESTRON TPS 4500IMW NET 75 Ohm INPUT INPUT GROUND 1 485 in 3 772 cm COMP 4 273 in 10 853 cm Y 24 Y C Z G 2 Wall Moun...

Page 7: ...nector is used to connect to other four wire devices in the Cresnet system If making network connections to Cresnet peripherals refer to Network Wiring on page 4 for details NET VIDEO This 10 position...

Page 8: ...r to the latest revision of the Cresnet Network Interconnect Drawing Doc 5411 The document can be obtained from the Downloads page CABLES and MANUAL Libraries of the Crestron website www crestron com...

Page 9: ...ire which share a pin on the network connector After twisting the ends tin the twisted connection with solder Apply solder only to the ends of the twisted wires Avoid tinning too far up or the tinned...

Page 10: ...TWISTED PAIR CABLE DEPENDING ON THE OPTION THE TWO JUMPERS ON THE NTSC PAL VIDEO FOUR PIN CONNECTOR REMAIN ATTACHED AS SHOWN OR ARE REMOVED CONNECT TO VIDEO SOURCE C NOTE If there is no video source...

Page 11: ...s installed into the electrical box as shown after this paragraph Use the orientation of the RJ45 connector as a guide Secure the TPS 4500IMW to the electrical box with the two 6 32 flat head slotted...

Page 12: ...reened insert plate supplied Affix the insert plate into the opening in the decora wallplate Refer to the diagram after this paragraph for the proper orientation of the insert plate with respect to th...

Page 13: ...pplied to the network Touchpanel is not responding Incorrect network wiring Touch screen to remove message and verify correct wiring to all connectors Further Inquiries If after reviewing this Operati...

Page 14: ...es are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron website www crestron com periodically for manual u...

Page 15: ...ered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warrant...

Page 16: ...Crestron Electronics Inc Operations Guide DOC 5913 15 Volvo Drive Rockleigh NJ 07647 02 01 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: