background image

DO

 

GUIDE

DO

 Check the Box

QTY

PART NUM.

1

TSW-UMB Universal Mounting Bracket

4517962

1

Pre-Construction Bracket

2035648

TSW-552

 

5" Touch Screen

DO

 Install the Device

The TSW-552 can be mounted into drywall and other surfaces 
or mounted onto a wall stud. When mounted into drywall and 
other surfaces, the touch screen protrudes just 1/2” (13 mm) 
from the mounting surface. 

To mount the TSW-552, use the following procedure:

1. For pre-construction applications, use standard drywall 

nails or screws to attach the included pre-construction 
bracket to a wall stud.

Pre-Construction Bracket Attached to a Wall Stud

CAUTION:

  Allow an air gap of at least 12” (305 mm) in 

the wall cavity above and below the TSW-552 for heat 
dissipation.

For post-construction applications, use the  
pre-construction bracket as a cutout template by turning 
the bracket to face the wall, ensuring it is level, and 
temporarily tacking it to the wall with finishing nails (not 
included) in the smaller holes around the cutout opening. 
Trace the cutout opening with an appropriate drywall saw 
(not included).

Post-Construction Installation of the TSW-UMB Universal Mounting 
Bracket into a Cutout

2. Loosen the two screws on the included TSW-UMB 

Universal Mounting Bracket, and then install the  
TSW-UMB bottom first into the opening.

Installing the TSW-UMB

3. Reach into the TSW-UMB and push the rear half back 

to ensure it is fully behind the mounting surface. Ensure 
the front of the TSW-UMB is level. Then, tighten the two 
screws to complete the installation.

CAUTION:

  To avoid damage to the bracket, do not 

overtighten the screws.

Completing the TSW-UMB Installation

4. Make connections to the TSW-552 using Crestron

®

 

power supplies and Crestron equipment. Power and 
data connection to the TSW-552 is provided by a single 
Ethernet cable connected to the LAN port at the rear of 
the unit. A Crestron PoE power supply or PoE-capable 
network switch is recommended (both sold separately). 
Apply power after the Ethernet cable is connected.

Hardware Connections for the TSW-552

5. Carefully hold the touch screen over the TSW-UMB and 

gently place it in position. The magnets on the rear of the 
touch screen hold it in place on the TSW-UMB.

Pre-Construction Bracket

Use a tie wrap to hold the cable 
until the TSW-552 is mounted.

TSW-UMB

Push the top surface 
downward to install 
the bottom half first.

TSW-UMB

Loosen both of the screws.

Push the rear half back.

Ensure the front is level.
Then, tighten both screws.

Reset Button

LAN PoE:

10BASE-T / 

100BASE-TX

Ethernet to LAN

Reviews: