PROGRAMMABLE OPTIONS
5. OEM Interface (RS901 Add-on Model):
This option controls this input selection for the Green Negative Start Trigger Wire. When using an Aftermarket Host
Alarm or Keyless Entry System: Leave the setting as “1 pulse” and connect the Green wire to the (-) Auxiliary output wire
of the Alarm or Keyless Entry System. For Factory Keyless entry systems (without a (-) Negative auxiliary output),
change the option to “3 Pulse” and tap the green wire into a Negative signal wire on the vehicle such as a Negative door
lock wire. Pressing the Factory remote lock button 3 times will produce 3 short negative signals to trigger a remote start.
6. Passive Starter Disable:
Note: Yellow/Black Negative Output must be programmed as an “Anti-Grind” for this feature. See option #12.
This option controls the unit’s Negative Anti-Grind output allowing it to come on automatically 1 min after the ignition has
been turned off. Note if you set this system up for a Passive Starter Disable/Anti-Grind, you must use the remote control
UNLOCK button when returning to the vehicle to deactivate it or vehicle will not start with key.
7. Horn Chirps on Remote Start:
This option allows the unit to provide 3 short chirps when for audible confirmation of a remote start. The horn output
wire must be connected for this feature.
8. Lock During/After Remote Start:
This option controls whether the unit will automatically lock during and after a remote Start abort or time-out.
9. Brown Output Wire Function: Trunk Pop or Dome Light Output
This option controls how the Brown output wire of the unit functions, either for Trunk pop or for Dome light
illumination.
10. +12V “Wake up” Pulse:
This option allows the unit to provide a 1-second pulse on the Pink main ignition output when unlocking. The Ignition
pulse serves to “Wake up” vehicle control modules or body computers that “time out” or go into power saving mode. This
is required on many late model Ford vehicles with a “Slam” lock system in order to actually unlock the vehicle after it has
been shut down for a short period of time.
11. No Option, Not used
12. Yellow/Black Wire Function: (-) Negative IGN or ANTI-GRIND / Starter Kill Output
This option controls the units Negative multi-function output. Default: Negative IGN output that turns ON and stays on
for the duration of the remote start. Use this wire to turn on Anti-theft bypass adapters for GM or Transponder systems.
When changed to an Anti-Grind, this output activates when the Lock button on the remote is pressed and activates
during a remote start. Anti-Grind is designed for use with an optional Starter disable relay (Not included).