background image

5

1b-2

drill depth

65mm / 2.5”

drill diameter

11mm

7/16”

Use 11 mm-7/16“ drill bit to drill 65mm - 2.5” holes on marks.

Utilice un 

11 mm-7/16“ para perforar la madera poco 65mm - 2.5” agujeros.

Utilisez un 

11 mm-7/16“ bits de forage pour percer 65mm - 2.5” po.

1b-2

CINDER BLOCK & CONCRETE INSTALLATION

Level wall plate, then mark 6 hole locations.

Nivele la placa de pared, a continuación, marque la ubicación de 6 agujeros.

Niveau de la plaque murale, puis marquer l’emplacement des 6 trous.

CINDER BLOCK & CONCRETE INSTALLATION

1b-1

!

!

WARNING!

Mounts are designed to be installed to a concrete wall with a minimum thickness of 8” and 

minimum density of 2000psi and 8”x8”x16” cinder block which meets ASTM C-90 specifica-

tions. Do not drill into mortar joints.  Do not install to a concrete wall or cinder block that has 

any type drywall or other finishing.

Se monta están diseñados para ser instalados en un muro de hormigón con un espesor 

mínimo de 8 “y la densidad mínima de 2000 psi y 8” x8 “x16” de bloques de cemento que 

cumple con ASTM C-90 especificaciones. No taladre en juntas de mortero. No lo instale en 

un bloque de pared o de cemento de hormigón que tiene cualquier tipo de paneles de yeso 

u otro acabado.

Montures sont conçus pour être installés sur un mur en béton d’une épaisseur minimale de 8 

“et la densité supérieure à 2000 psi et 8” x8 “x16” en blocs de béton qui rencontre la norme 

ASTM C-90 du cahier des charges. Ne percez pas dans les joints de mortier. Ne pas installer 

sur un mur ou cendre bloc de béton qui a une cloison sèche de type ou d’un autre finition.

1b-1

RSF100-0002

Summary of Contents for RSF100

Page 1: ...l installation veuillez contacter le service client le de Crimson AV ou un installateur qualifi Crimson AV n est pas re sponsable des dommages ou des pr judices caus s par un montage un assemblage ou...

Page 2: ...2 M4 M5 Spacer R 4 M6 M8 Spacer S 4 M8 x 40mm P 4 M8 x 16mm N 4 M8 x 20mm O 4 M8 Washer U 12 8mm x 65mm A 4 B 4 M4 x 12mm F 4 M5 x 30mm I 4 M6 x 12mm J 4 M6 x 20mm K 4 M6 x 30mm L 4 M5 x 12mm H 4 M4 x...

Page 3: ...localisateur de montants pour localiser les centres de deux piliers structurels WOOD STUD INSTALLATION 1a 1 1a 1 1a 2 Using level draw a vertical line at stud center Con un nivel trace una l nea verti...

Page 4: ...a 3 Install only to wood studs or wood joists that are a minimum of 2 x4 the wall or ceiling where the mount is being attached may have a maximum drywall thickness of 5 8 Instale solamente a los poste...

Page 5: ...90 specifica tions Do not drill into mortar joints Do not install to a concrete wall or cinder block that has any type drywall or other finishing Se monta est n dise ados para ser instalados en un mu...

Page 6: ...verrouillage attach verrouillage sup port E pour montage mural plaque C Tourner la vis sup rieure pour verrouiller en place 3 2 Fasten wall plate to wall using screw A and washer U Fije la placa de pa...

Page 7: ...l fourni avec un tournevis Outils main seulement 4 1 ATTACH MOUNT BRACKETS If screws bottom out use washers not included to eliminate slack Si los tornillos toc fondo a continuaci n utilizar arandelas...

Page 8: ...t align es avec les supports de suspension Tournez les vis sup rieures sur les supports de verrouillage pour les fixer en place LOCK HANGER BRACKETS INTO PLACE 6 5 6 Hook top of bracket over the top o...

Page 9: ...for incidental or consequential damages This includes but is not limited to any labor charges for the repair of Crimson AV LLC products performed by anyone other than Crimson AV LLC Specifications ar...

Page 10: ...paration de produits Crimson AV LLC par une personne ne travaillant pas pour Crimson AV LLC Les sp cifications sont sujettes changement sans pr avis GARANTIE NOTICE TO CUSTOMERS OUTSIDE THE UNITED ST...