Table of references according to the various options
Item
MAX Current
Number of
inputs
Number of
Outputs
IG
Terminal
RCE/100-1E-2IG
100A
1
2
YES
RCE/100-1E-3IG
3
RCE/100-2E-3
2
NO
RCE/150-1E-2IG
150A
1
2
OUI
RCE/150-1E-3IG
3
RCE/180-1E-2IG
180A
2
RCE/180-1E-3IG
3
RCE/200-1E-3IG
200A
4
I
NSTALLATION
4.1
ISOLATOR POSITIONING
Install the RCE in a dry place free from flammable substances.
Position the isolator on a flat surface.
Install the isolator so that the heatsinks (small fins) are vertical.
A clearance zone of around 100mm around the splitter is recommended for ventilation.
Do no put anything against, or on the top of RCE.
Do not install the isolator on the engine.
It is preferable to install the RCE as close as possible to the battery banks (see section of the cables paragraph).
4.2
F
IXING AND TIGHTENING THE ISOLATOR
The isolator should be fixed correctly with a system of screws, washers, nuts and lock nuts to prevent falls due to
vibrations.
Tables of tightening according to the sizes of the threaded rods
Item
Max Current
(A)
ø
Threaded
rod input (Iso)
ø
Threaded rod
output (Iso)
RCE/100
100
M6
M6
ø
Threaded rod(Iso)
Tightening (N.m)
RCE/150
150
M8
M6
M6
3,83
RCE/180
180
M8
M8
M8
7,26
RCE/200
200
M10
M8
M10
14,62