24
4.4.1
T
ERMINOLOGY AND SYMBOLS
te : input of the isolator wired to a regulator.
BAT+ : Output wired to a battery bank
IG (Ignition) : input allowing an excitation voltage on B+ terminal (see 3.4.3).
BAT- : wired to negative terminal of the battery.
LED indicator.
4.4.2
C
IRCUITS WITHOUT
IG
WIRING
For generators (alternators, solar panel regulators, etc.) that do not require an excitation voltage, circuit is very simple:
- An electrical wire between BAT - terminal of the RCE and the negative terminal of the battery (the cross-section should
be 1mm²).
- A cable of the correct cross-section (see table of cable cross-sections) between the + terminal of the RCE and the
regulator output d 'alternator.
- Connect all the outputs BAT+ to you battery banks (see table of cable cross-sections).
IT IS IMPERATIVE TO CONNECT THE BAT-
TERMINAL OF THE RCE TO THE COMMON
NEGATIVE BATTERY BANK.
Tout manquement détériorera les composants
du répartiteur et provoquera sa dégradation.
Bow thruster
batteries
House
batteries
Starter
batteries
fuse
fuse
fuse
Alternator
fuse
RCE
Isolator
Circuit
breaker
Circuit
breaker
Circuit
breaker
To
consummers