25
4.4.3
C
IRCUITS WITH
IG
WIRING
The IG connection can be used to start regulated alternators (or some solar panel or wind turbine regulators).
These alternators must be excited with an excitation voltage on one of their terminals.
In this case the IG terminal must be connected to the battery voltage coming from the ignition key.
If the voltage source is solar or wind, or other, the IG terminal must be connected to the positive pole of a battery
through a switch.
Starter
batteries
House
batteries
Bow thruster
batteries
Circuit
breaker
Circuit
breaker
fuse
fuse
fuse
fuse
Alternator
RCE
Isolator
Circuit
breaker
IT IS IMPERATIVE TO CONNECT THE BAT-
TERMINAL OF THE RCE TO THE COMMON
NEGATIVE BATTERY BANK.
.
Tout manquement détériorera les composants
du répartiteur et provoquera sa dégradation.
To
consummers