6
OPERATION
•
To start the machine place it on a flat level surface and turn the engine switch to ON.
•
Move the choke lever to the closed position.
•
Press the priming pump until fuel is seen in the fuel tube. See engine user manual.
•
Pull the starter slowly until resistance is felt, pull briskly to start but do not pull out the recoil
rope to the end. Return the starter grip to the normal position.
•
Open the choke lever as the engine warms up.
•
Operate the unit at high speed to ensure the clutch is engaged and the correct compaction
is achieved.
•
Avoid sharp bends when in use or damage to the flex shaft could result.
•
Do not use as an external vibrator or leave running for extended periods out of the concrete
as the unit needs to be immersed in the wet concrete to remain cool.
ENGINE
The engine user manual is enclosed.
PORTABLE CONCRETE VIBRATORS SPECIFICATION CHART
MODEL
PV45HRN
Shaft Size
45mm
Frequency
9000vpm
Engine Make
Honda
Engine
1.3hp GX35
Starting System
Recoil start
Engine Features
4-stroke OHV
Fuel Type
Petrol
Fuel Tank
0.65L
Noise Level
93dB at 1m
Weight
11kg
Manufacturer’s Warranty
Two years
Engine Warranty
Refer to Honda
Summary of Contents for PV45HRN