3.3. Device responses to emergencies
Local device
Remote device
Condition
Indicators
and relay
AIS Output
to E1 Ports
Indicators
and Relay
AIS Output
to E1 Ports
Power failure
All indicators: Off
Relay: Alarm
LOS: On
Relay: Alarm
To all ports
Loss of input signal from
link
LOS: On
Relay: Alarm
To all ports RERR: On
High link input signal error
rate
LERR: On
Relay: Alarm
To all ports RERR: On
E1 port N configured as
«Unused»
PORT N STATE: Off
Loss of E1 port N input
signal (port is «In use»)
PORT N LOS: On
Relay: Alarm
To port N
Loss of E1 port N input
signal (port is «Unused»)
PORT N STATE: Off
To port N
AIS is being received at the
E1 port N
To port N
Local link loopback is
enabled
TST: flashes
To all ports
Remote link loopback is
enabled
TST: flashing by
double flashes
TST: flashes
To all ports
E1 port N loopback is
enabled
PORT N STATE:
flashes
To port N
E1 port N tributary
loopback is enabled
PORT N STATE:
flashing by double
flashes
To port N