Section 4. Control via the console port
The front panel of the multiplexer is equipped with a DB9 connector (female) with a RS-
232 interface, for connecting a control terminal (console). The console may be used to
view current device modes, link states, local and remote error statistics, to select device
modes and save them in non-volatile memory. For the console, the data rate is equal to
9,600 bits/s, 8 bits per character, no parity, 1 stop bit.
!
When the terminal is connected, the RTS signal (for stream control) must be
provided.
4.1. Upper level menu
The console interface is designed as a simple hierarchical menu. To select a command,
you must enter its number. To return to the upper-level menu, you must press <Enter> (or
<Return>). An example of the main menu is given in the picture:
Cronyx FMUX / 4E1-SNMP revision D, 28/07/2004
Mode: Normal; Sensor=Open
Link: Ok
1. Link statistics
2. Port statistics
3. Event counters
4. Loopback...
5. Test...
6. Configure...
7. Login to remote FMUX
0. Reset
Command: _
The upper line contains device model name, revision code and firmware date.
The '
Mode
' line shows the 'alarm' state and the state of the external input sensor:
• 'Normal' – normal state – or «Alarm» – the 'alarm' state;