FMUX/S-4E1-E2 Multiplexer
1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567
1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901234567
Copyright © 2007 Cronyx
37
•
'Trap destination IP address: ...'
– the IP address for sending emergency event traps.
'Sensor input' command
The '
Sensor input
' command switches the alarm signal generation mode of the remote
device to the external input sensor. The external sensor has two operating modes: 'Alarm
on closed' (default) and 'Alarm on open'. In the 'Alarm on closed' mode, when contact 3
connects to contact 7, the remote device goes into the emergency alarm status. (See
section "Emergency alarm" for more details).
'Factory settings' command
The '
Factory settings
' command restores the device modes to their initial state:
• E1 ports usage mode – all ports are used («In use»);
• alarm signal input sensor contacts mode – on closed ('Sensor input: Alarm on closed').
The '
Factory settings
' command does not affect the IP address and SNMP protocol pa-
rameter settings (see the 'SNMP' menu).