2. INTRODUCTION

The DO7 is an accurate bench/portable Digital Ohmmeter for the measurement of resistance in the
range 0.1µ

 to 60

.  It offers you the four terminal resistance measurement method to eliminate

the effect of lead resistance.  The measured values are displayed on a 4-digit LCD display; an
overflow of the selected range is also indicated.

Display range 6000

Simple push-button selection of the range required, ensures that the DO7 may be easily used by
unskilled personnel.  Error and status warnings are illuminated when appropriate.  The utmost care
has been taken to ensure that the ohmmeter will withstand an accidental mains voltage applied to
the measuring terminals, but it is not recommended that voltage should be applied.

3. MEASURING 

PRINCIPLE

The measurement is true 4 terminal, using the Kelvin principle.  A stable current is produced
across the resistance to be measured via the C terminals, and the voltage drop across the Rx is
measured at the P terminals.  This potential drop is then compared against the voltage drop
across internal standards.  The ratio of these is then converted to the resistance value of Rx and
displayed in ohms on the digital display.  High accuracy and long term stability is achieved by
using our own manufactured internal resistance standards.

4. CASE 

DESIGN

The case is ruggedly constructed from an ABS/polycarbonate alloy, coloured safety yellow.  A
strong internal sub-frame ensures that the DO7 will withstand the harshest of environments.  The
front panel is a reverse printed polycarbonate overlay with clear and unambiguous text.

5. MAINTENANCE

Normally no maintenance is required other than cleaning with a moist cloth.  Avoid aggressive
detergents or solvents.

CAUTION:

  

Before any maintenance, repair or exchange of parts or fuses, the instrument
must be disconnected from the mains supply and all power sources.  In the event
of a fault occurring, the instrument should be returned to our factory or Agent.  A
mains fuse is fitted to the mains inlet socket on the front panel, and should be
replaced if necessary.

CAUTION:

  

Disconnect mains lead and all connecting leads, before removing fuse holder.
Replace only with the correct fuse type, ie. according to the following chart.

Line

Voltage

Selection

Range

VAC

47-63Hz

Fuse (250V)

IEC 127

5 x 20 mm

100V
120V

87-110V

104-132V

2.5A (T)

220V
240V

191-242V
209-264V

1.25A (T)

Maximum Input Power : 80VA

The input circuits are protected by a 6 AMP fuse located in a holder on the main printed circuit
board.  Access is gained by removing the top cover.  Only replace with the correct fuse type as
below

.

10A Am  550V rms   HRC Ceramic Cartridge 10 x 38 mm

IEC 269-2-1  NFC63-210

Summary of Contents for DO7

Page 1: ...DIGITAL MICROHMMETER TYPE DO7...

Page 2: ...T 5 7 TECHNICAL DATA 5 8 DESCRIPTION OF CONTROLS 6 Range Selection 7 Error Status Lamps 7 9 METHODS OF MEASUREMENT 7 10 POWER UP 9 11 MEASUREMENT 9 Over Range 9 12 REMOTE 10 13 PRINTER OUTPUT 10 14 PR...

Page 3: ...the apparatus make sure that it is set to the voltage of the power supply The mains plug shall only be inserted in a socket outlet provided with protective earth contact The protective action must no...

Page 4: ...bility is achieved by using our own manufactured internal resistance standards 4 CASE DESIGN The case is ruggedly constructed from an ABS polycarbonate alloy coloured safety yellow A strong internal s...

Page 5: ...use The batteries will recharge in approximately six hours and the DO7 lid should be open to allow for maximum ventilation IMPORTANT Always connect instrument to mains supply after use and top up batt...

Page 6: ...ing currents Measuring time Approx 0 5 seconds Polarity Forward and reverse measurement current may be selected plus average mode which automatically displays the average value of positive and negativ...

Page 7: ...DO7 Issue 7 2001 6 8 DESCRIPTION OF CONTROLS 4 Digit LCD Display Range Switches On Off Power Switch Calibration Measuring Terminals RS232 Printer Socket Battery Status Indicator Mains Socket Remote S...

Page 8: ...supply is connected to the instrument CAL Calibration mode has been initialised by the key switch and the instrument is in calibration mode O C One of the measuring leads is open circuit LEAD too high...

Page 9: ...CROPICO LTD DO7 Issue 7 2001 8 Fig 9 1 Combined current and potential probes Fig 9 2 Various types of resistors...

Page 10: ...NDBY state Should you wish to initialise a continuous reading then press the LOCK ON buttons The measurement will continue until the STANDBY button is pressed or the ON button pressed again An audible...

Page 11: ...he last value measured when switching from ON to STBY This key toggles ON OFF Baud Rate This key will display the currently set value when pressed To change the value press CLE to clear and then use t...

Page 12: ...ENT REQUIRED Cropico Calibration Standard Type MTS2 Set of 2 low thermal emf leads Set of 2 general purpose leads 10A rating Calibration key no 901 17 PREPARATION 17 1 Ensure all retaining screws are...

Page 13: ...FICATION 19 1 Ensure that the panel switch is set to RUN and the calibration key is removed 19 2 Set the calibration rig to 40 Ohm Zero 19 3 Set the DO7 to 60 Ohm range ve and press LOCK ON Wait for t...

Page 14: ...ay be used in place of the Cropico Calibration Standard The standards must have an uncertainty better than 0 01 if the full calibration accuracy is to be achieved Full consideration of the DO7 measuri...

Page 15: ...CROPICO LTD DO7 Issue 7 2001 14...

Page 16: ...has been detected This test is performed at power up and failure is indicated by the HELP message 21 2 Turn the DO7 power ON Wait for the display test to complete and the HELP message to appear 21 3...

Page 17: ...CROPICO LTD DO7 Issue 7 2001 16...

Page 18: ...e leads HSO2 RS Duplex Handspikes as HSO2 but with remote start button fitted LSO3 Large Kelvin clips with 3 metre leads accept cables and bars up to 38mm diameter LSO4 As LSO3 but with 3 metre leads...

Page 19: ...S THERMOCOUPLE REFERENCE JUNCTIONS THERMOCOUPLE SELECTOR SWITCHES PT100 SIMULATORS PRECISION WATTMETERS INSULATION TEST SETS UNIVERSAL CALIBRATORS POWER ANALYSERS HIPOT TESTERS ELECTRICAL SAFETY TESTE...

Reviews: