6. BATTERY 

CHARGING

The DO7e has a built-in rechargeable sealed lead acid battery, which is fully charged when 
delivered. To ensure good service life from the battery, the DO7e incorporates a sophisticated 
battery management system. Low battery condition is indicated by a panel mounted LED.

The battery charger is built in and the instrument may be connected to 110/ 230 volts supply. 
The appropriate voltage setting must be selected on the inlet socket and the correct fuse 
inserted. The LINE LED will illuminate on the front panel to indicate when the mains supply is 
connected.

Charging is automatically controlled with built-in protection circuits eliminating the possibility of
over-charging. The display will blank when the battery voltage is too low to sustain 
measurements, and the low battery indicator will illuminate. The battery will recharge in 
approximately six hours, and the DO7e lid should be open to allow for maximum ventilation.

IMPORTANT: Always connect instrument to mains supply after use and top up battery. 
Instruments should be stored with batteries fully charged, and when stored for long 
periods the batteries should be recharged each month.

Should the batteries become deeply discharged due to being left for long periods without 
charge, then the internal charger will automatically sense the battery state and will trickle 
charge with a very low current to restore the batteries before automatically switching to 
fast charge. This low current charge may take up to 20 hours to restore the batteries. 
Continuous charging will not damage the batteries and will, in fact, keep them in best 
condition.

BATTERY

The internal battery is a sealed lead acid type. Care should be taken when disposing, and it 
may be returned to Cropico for safe disposal.

Any regulations and directions applying to the disposal of such material must be applied.

Do not dispose of battery in fi re.

Do not short circuit.

Do not crush, puncture, open, dismantle or otherwise mechanically interfere with the battery.

NOTE: If storing for long periods, the batteries should be fully recharged every six months.

Digital Microhmmeter Type DO7e

Operating Instructions

5

Summary of Contents for DO7e

Page 1: ...en Hill South West Industrial Estate Peterlee Co Durham SR8 2SW England Tel 44 0 191 586 3511 Fax 44 0 191 586 0227 www cropico co uk sales cropico co uk Digital Microhmmeter Type DO7e Operating Instructions ...

Page 2: ......

Page 3: ...ocopying recording or in any manner without prior written consent from CROPICO This also applies to accompanying drawings and diagrams Due to a policy of continuous development CROPICO reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment ...

Page 4: ...rise yourself with the appropriate local separate collection system for electrical and electronic products Please dispose of this product according to local regulations Do not dispose of this product along with normal waste material The correct disposal of this product will help prevent potential negative consequences for the environment and human health User Note These Operating Instructions are ...

Page 5: ... 8 DESCRIPTION OF CONTROLS 7 Range Selection 8 Error Status Lamps 8 9 METHODS OF MEASUREMENT 8 10 POWER UP 11 11 MEASUREMENT 11 Current Mode 11 Over Range 11 Low Battery 12 12 Connections 12 13 REMOTE 12 14 PROTECTION 12 15 CALIBRATION PROCESS 12 16 EQUIPMENT REQUIRED 13 17 PREPARATION 13 18 CALIBRATION 13 19 USING DISCRETE RESISTANCE STANDARDS 14 Digital Microhmmeter Type DO7e Operating Instructi...

Page 6: ...protective action must not be negated by the use of an extension lead without a protective conductor WARNING Any interruption of the protective conductor inside or outside the apparatus or disconnection of the protective earth terminal is likely to make the apparatus dangerous Intentional interruption is prohibited When the apparatus is connected to its mains supply terminals may be live and the o...

Page 7: ...achieved by using Specially selected components 4 CASE DESIGN The case is ruggedly constructed from an ABS polycarbonate alloy coloured safety yellow A strong internal sub frame ensures that the DO7e will withstand the harshest of environments The front panel is a reverse printed polycarbonate overlay with clear and unambiguous text 5 MAINTENANCE Normally no maintenance is required other than clea...

Page 8: ...trument to mains supply after use and top up battery Instruments should be stored with batteries fully charged and when stored for long periods the batteries should be recharged each month Should the batteries become deeply discharged due to being left for long periods without charge then the internal charger will automatically sense the battery state and will trickle charge with a very low curren...

Page 9: ...me Approx 0 5 seconds Polarity Forward and reverse measurement current may be selected plus average mode which automatically displays the average value of positive and negative polarity measurement Ranges and Accuracy NOTE Temperature coefficient to be added to uncertainty when operating outside the range 15 to 25 C NOTE Measurements on the lowest range 60µΩ may have an additional zero offset of u...

Page 10: ...y CAL Key Current Mode Keys Measure Key Remote Start Socket 8 DESCRIPTION OF CONTROLS Digital Microhmmeter Type DO7e Operating Instructions 7 Measuring Terminals 4 Digit LCD Display Remote Start Socket Measure Key Current Mode Keys CAL Key OFF Key On Key Auto Range Key Mains Socket ...

Page 11: ...LED and over range will be indicated by the display reading An Auto range facility is also provided pressing the AUTO key sets the DO7e in to auto range mode Error Status Lamps These LEDs will light to indicate the instrument status LINE Mains supply is connected to the instrument LOBAT Indicates low remaining battery capacity CHG Indicates that the internal battery is charging O C One of the meas...

Page 12: ...pecial test fixtures may have to be made for the user to suit particular applications d Fig 9 2 illustrates connections to various types of test resistors e When measuring 4 terminal resistance standards do not use the combined current and potential probes Make four separate connections to the current and potential terminals Digital Microhmmeter Type DO7e Operating Instructions 9 ...

Page 13: ... P2 U Connections to Current Shunt C1 I C2 I P1 U P2 U Fig 9 2 Various types of resistors Digital Microhmmeter Type DO7e Operating Instructions 10 C1 I C2 I P2 U P1 U Connections to Stud Terminals C1 I P1 U P2 U C2 I Connections to Cable Joint Connections to Current Shunt C1 I P1 U C2 I P2 U ...

Page 14: ...AS key should be pressed again Should you wish to initialise a continuous reading then press and hold the MEAS key until a long bleep is heard this will lock the measurement in continuous mode Note continuous measurement is not possible on the lowest 6mΩ range The measurement will continue until the MEAS key is pressed again The DO7e will automatically power off after 5 minutes with no key activit...

Page 15: ...ng applied to the terminals A large 6 Amp fuse is fitted internally to the C measuring line and a gas discharge tube GDT is across the C terminals If voltages above approximately 90V are applied to the measuring terminals the GDT will strike effectively shorting the C terminals through the 6 Amp protective fuse which will interrupt the circuit The fuse fitted will interrupt up to 40 000 Amps The P...

Page 16: ...wer ON whilst holding down the CAL key 17 6 Leave for a few minutes to stabilise 18 CALIBRATION ENTERING A PASSCODE CALIBRATION 1 Hold down CAL key whilst powering up the DO7E displays CODE 2 Enter the 4 digit passcode default is 9252 and press OK 3 If the code was incorrect a long beep is emitted and the user should start again from 2 4 If correct the DO7e displays zero eg 0 0 and is now in Calib...

Page 17: ...PASSCODE 1 Carry out 1 to 4 as above using the existing passcode 2 Press and hold the CLE key for 2 seconds the DO7e displays CODE 3 Enter the new 4 digit passcode and press OK the DO7e displays CODE again 4 Re enter the new 4 digit passcode and press OK 5 If the new passcode was not entered correctly both times a long beep will be emitted and the process must be repeated from 3 6 If correct the D...

Page 18: ... ZERO measurements connect the C1 and C2 leads to the C2 terminal of the standard see Fig 20 2 FULL SCALE CALIBRATION P1 P2 LEADS PURE COPPER MULTI STRANDED C1 C2 LEADS 10A RATING 55 0 15MM Fig 20 1 ZERO CALIBRATION P1 P2 LEADS PURE COPPER MULTI STRANDED C1 C2 LEADS 10A RATING 55 0 15MM Fig 20 2 END OF TEST PROCEDURE Digital Microhmmeter Type DO7e Operating Instructions 15 C1 P1 P2 C2 C1 P1 P2 C2 ...

Page 19: ...clamp options Description Duplex Handspikes with 2 5 metre lead length current and potential spikes suitable for plate or Bussbar measurements Duplex Handspikes as a HS01 P but with 2 5 and 15 metre lead lengths Large Kelvin clips with 3 metre lead length suitable for attaching to rods bars or cables up to 38mm diameter As LS03 P but with lead lengths 3 and 15 metres Executive lead set consisting ...

Page 20: ...61010 2 030 2010 Safety requirements for electrical equipment for measurement control and aboratory use Part 2 030 Particular requirements for testing and measuring circuits BS EN61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements Performance The instrument operates within specification when used under the conditions in the abov...

Page 21: ...ntact Tel 44 0 191 587 8718 For Service and Calibration Contact Service Department Seaward Group Unit 11 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2LS England Tel 44 0 191 587 8739 Fax 44 0 191 587 8737 E mail service seaward co uk CROPICO is a division of ...

Page 22: ...SISTANCE STANDARDS DIGITAL THERMOMETERS THERMOCOUPLE SIMULATORS PT100 SIMULATORS INSULATION TEST SETS UNIVERSAL CALIBRATORS HIPOT TESTERS ELECTRICAL SAFETY TESTERS Phone fax or e mail for further information on the above or for a copy of our general catalogue Phone 44 0 191 5863511 Fax 44 0 191 5860227 E mail sales cropico com Website www cropico com ...

Page 23: ......

Page 24: ...610019 Rev 5 ...

Reviews: