29
28
18/09/2016
LP-OMLINK-B
BROADCAST AND TURF APPLICATIONS
L/HA 50CM NOZZLE SPACING
Nozzle type Pressure bar Flow rate
l/min
5
kph
6
kph
7
kph
8
kph
10
kph
12
kph
16
kph
110-015
1.0
0.346
81.6
68.0
48.3
51.0
40.8
34.0
25.5
1.5
0.424
101
84.0
72.0
63.0
50.4
42.0
31.5
2.0
0.490
115
96.0
82.3
72.0
57.6
48.0
36.0
3.0
0.600
142
118
101
88.5
70.8
59.0
44.3
4.0
0.693
163
136
117
102
81.6
68.0
51.0
5.0
0.775
182
152
130
114
91.2
76.0
57.0
6.0
0.849
199
166
142
125
99.6
83.0
62.3
110-02
STANDARD
1.0
0.462
110
92.0
78.9
69.0
55.2
46.0
34.5
1.5
0.566
134
112
96.0
84.0
67.2
56.0
42.0
2.0
0.653
156
130
111
97.5
78.0
65.0
48.8
3.0
0.800
190
158
135
119
94.8
79.0
59.3
4.0
0.924
218
182
156
137
109
91.0
68.3
5.0
1.033
245
204
175
153
122
102
76.5
6.0
1.131
269
224
192
168
134
112
84.0
110-025
1.0
0.577
137
114
97.7
85.5
68.4
57.0
42.8
1.5
0.707
168
140
120
105
84.0
70.0
52.5
2.0
0.816
194
162
139
122
97.2
81.0
60.8
3.0
1.000
238
198
170
149
119
99.0
74.3
4.0
1.154
274
228
195
171
137
114
85.5
5.0
1.291
310
258
221
194
155
129
97.0
6.0
1.414
339
283
242
212
170
141
106
110-03
1.0
0.693
163
136
117
102
81.6
68.0
51.0
1.5
0.849
199
166
142
125
100
83.0
62.3
2.0
0.980
230
192
165
144
115
96.0
72.0
3.0
1.200
283
236
202
177
142
118
88.5
4.0
1.386
326
272
233
204
163
136
102
5.0
1.549
365
304
261
228
182
152
114
6.0
1.697
401
334
286
251
200
167
125
110-04
1.0
0.924
218
182
156
137
109
91.0
68.3
1.5
1.113
269
224
192
168
134
112
84.0
2.0
1.306
310
258
221
194
155
129
96.8
3.0
1.600
379
316
271
237
190
158
119
4.0
1.848
437
364
312
273
218
182
137
5.0
2.066
490
408
350
306
245
204
153
6.0
2.263
535
446
382
335
268
223
167
4. Select Nozzle Type & Size according to:
»
Chemical recommendations
»
Application rate required
»
Pressure setting
»
Swath width
»
Chosen speed of travel. (Use actual speed of
travel, refer to step 2).
5. Fit the selected nozzles to the boom as per
the nozzle manufacturers specifications.
6. Check the nozzle accuracy as outlined
above in spraying information.
7. Add the correct amount of chemical to the
tank as per the directions on the chemical
label.
8. Adjust the boom height to suit your nozzles
as explained in the Nozzle section in
spraying information above.
9. Don’t forget to record your data for future
reference.
NOTE
To find more information on how to
calibrate a boom for varying application
rates:
»
Refer to the Croplands web site at www.
croplands.com.au or
»
Contact the Croplands Customer Service
or
»
Technical Support: Phone 1300 650 724.