HT-OMCROPLINE-E
86
SECTION 7
SPRAYING INFORMATION
CALIBRATION WORK SHEET
SECTION 7
SPRAYING INFORMATION
CALIBRATION WORK SHEET
Step 1
Check the Sprayer is in Good Working Order
Step 2
Determine Actual Speed of Travel
Measure and mark a straight path of 100 metres
(or more) of travelling conditions similar to the
orchard or vine yard you are going to spray.
Half fill the spray tank & record the time (in
seconds) to travel the measured distance.
Make sure that the tractor is travelling at spraying
speed when you pass the start and finish marks and
ensure the fan and pump are at operational speed.
If you have a hectare metre or automatic controller
you need to check the speed calibration of the
controller.
Tractor model
Gear
Range
Dual power
Engine RPM
Speed Km/h
Kilometres per Hour = Distance traveled
(m) x 3.6/time (seconds)
Step 3
Determine Spraying Volume Required
It is essential to determine the liquid volume per
hectare required to effectively spray a crop without
overspraying or underspraying.
Use your own experience or a registered rate
calibration consultant to determine effective
volume in litres per hectare.
........................................................ litres/ha
Step 4
Determine Sprayer Configuration
Number of rows
to be sprayed
in one pass
= 1
Total number
of nozzles to be
used:
Step 5
Determine ideal spray pressure (bar)
Step 6A, B, C
Determine & Select Nozzles
Determine nozzle flow rate required:
Litres/Minute
=
Litres/Ha x Km/hr ÷ 600 ÷ Total Number
of Nozzles Used x Row Spacing (m)
x Number of Rows in One Pass
x ÷ 600 ÷ x
= litres/minute/for all nozzles
(divide by 2 for each half)
Step 6D Calibration Work Sheet ; Fieni 920 DSV Fan ; Disk & Core Nozzles
Front Spray Ring
Rear Spray Ring
Nozzle
Disc No.
Core No.
Discharge
Spray angle
Nozzle
Disc No.
Core No.
Discharge
Spray angle
Top 1
Top 8
2
9
3
10
Middle 4
Middle 11
5
12
6
13
Bottom 7
Bottom 14
one side =
L/min
FRONT
Spray Ring
one side =
L/min
REAR
Spray Ring
Pressure
L/Min ALL NOZZLES
Step 7
Fit & Test Selected Nozzles
The most important calibration is to test for actual
litre per hectare.
Fill your spray tank to overflowing and run the
sprayer for one minute, at the above operating
settings, and record the total litres per minute used.
Output/min/side (l/min)
=
Output (litres) ÷ Time (minutes)
÷
= litres/minute
Step 8
Calculate the Actual Application Rate
To calculate actual application rate (litres per
hectare), use the following formula:
Application Rate (l/ha)
=
Total Sprayer Output (l/min) x 600
÷ Speed (Km/hr) ÷ Row Spacing (m)
÷ Number Rows in One Pass
x 600 ÷ ÷ ÷
= litres/ha
DISCLAIMER:
Because of the many variable factors involved Croplands can not be
held responsible for any downgrading or loss of crop resulting
from the use of any information in this manual. This is issued as a guide
only and subject to acceptance of this disclaimer.