GP-OMCP12-D
16
SECTION 4
PRE-OPERATION
UNLOADING
Take care when loading / unloading sprayers. Many of
these sprayers exceed the capacity for one or two people
to manually handle. Most models have suitable sling
pickup points. Be careful of the balance.
All loading / unloading should be done with tanks empty.
See Section 5 of the Safety manual.
FITMENT
Make sure the unit is securely fastened. Some models will
require tie down straps, other models require bolting the
unit to a vehicle.
Remember to factor in the weight of a full tank when
determining the mounting, and always consult the vehicles
manual for load ratings and suitable mounting points.
Check all nuts, bolts and plumbing fittings for tightness.
Check the filters.
If a boom is fitted, read the boom manual.
HOOK-UP
Power connection. All 12-volt models are supplied with
a heavy-duty power cable (UP-119B), which includes
connections at the pump end.
Connect this power cable to a reliable 12-volt battery.
• The red (+ive) power lead to the positive (+ive)
battery terminal, and
• The black (-ive) power lead to the negative (-ive)
battery terminal.
Failure to connect leads to a battery of the correct voltage
will cause damage to the electric motor.
The standard loom is supplied with alligator-type battery
clamps which will suffice provided there is room for
this type of connection, providing they can be securely
attached to the battery terminals.
Using permanent connections attached to the battery
terminals is preferred – these are not supplied but ask your
Croplands dealer to assist with this battery connection
unless you can do so yourself.
It is possible to have a male power socket fitted to the
loom to plug into a standard vehicle 12-volt connection,
but before doing so ensure the socket connection on the
vehicle can supply a minimum of 12 volts and that the
circuit has a minimum of a 20-amp fuse installed.
For the pump to perform correctly, strong and continuous
power supply is a must.