Connections
This section explains the various connections of the NEXUS AM.
NEXUS AM Deactivator connections explanation
1
Relay connections, potential free. Can be triggered during deactivation.
Nominal switching capacity: 2A, 30VDC
Normally Open (NO), Common (COM) and Normally Closed (NC)
2
I/O connections: GND and I/O-1. Can be used as input for a foot switch.
3
External LEDs connector. Type: RJ-11
Do not connect a telephone line to this connector!
4
Termination switch. Used to terminate the Field Bus. Must be activated when this
device is the last device in the Field Bus.
Pushed: terminated, a red LED between the relay and I/O connectors lights up.
Not pushed: not terminated.
5
BUS-A: Field bus connector
6
BUS-B: Field bus connector
7
Main fuse: 160mA (230VAC) or 315mA (115VAC)
8
Mains power inlet: 230VAC (default setting) or 115VAC
Use SW1 to switch to 115VAC if required (see chapter 3.3).