NEXUS AM Deactivator
Configuration
v2.1
Page 18 of 26
7.2.1
Manual synchronization
By default the transmission burst can be synchronized manually by dragging and moving
the burst throughout the complete 20ms time base.
Just hover the mouse cursor over our transmission burst (the cursor will change to a
horizontal double arrow) and press down your left mouse button. While keeping the
mouse button pressed, move the transmission burst and position it on top of the other
system’s transmission burst. Together with moving the transmission burst, also the
receiver and reference windows will move automatically since they have a fixed reference
to the transmission burst.
Figure 10
shows the deactivator’s transmission burst having been placed exactly over the
transmission burst of another AM system/deactivator. The deactivator’s tag detection
window is in a clear part of the detection band, which results in proper performance of the
deactivator.
7.2.2
Automatic synchronization
Click the Automatic synchronization button
to open the underlying menu.
Start automatic synchronization mode
7.2.2.1
When this option is selected, the software will detect the best position for the
transmission burst. Just click the Automatic Sync button and within 10 to 15 seconds the
software will have determined the best burst offset position.
This option can only be used when other AM systems or AM Deactivators are visible in
the synchronization screen.
Temporarily disabling entrance bursts
7.2.2.2
When you start synchronizing entrance(s), start by selecting the Synchronization page of
the first entrance. It is very useful to switch the transmission bursts of all other entrances
off, so you can determine if there are any other AM systems or deactivators in the area,
to which you must synchronize your deactivator.
Click on the green checkmark
in front of the entrance/deactivator name to disable the
transmission burst of that entrance/deactivator. The disabled icon
will appear,
indicating the transmission burst for that entrance/deactivator is switched off. Click this
icon again to switch the burst on again.
When you leave the Synchronization page, all disabled entrances/deactivators will
automatically start bursting again.