40
Manual XM3 Remote Programmer: Version 4.1
4.8
- Program Overall Time-out
In Program mode, the XM3 has a timer which is used to count the number of
seconds since the last key-press on the Remote Programmer.
If the count exceeds a pre-set value, the XM3
generates an alarm and
resumes normal operation.
Format
:
seconds
Min. value
:
5
Max. value
:
255
Default value
:
30
Step Action
Result
1
Present the original Remote
Programmer
Program mode entered
2
Activate “Overall Time-out”-mode
“Overall Time-out”-mode is
entered
3 Set
Overall
Time-out
XM3 resumes normal
operation
4
Repeat the procedure starting from
step 1 if multiple Remote
Programmers need to be added or
copied.