78
Manual XM3 Remote Programmer: Version 4.1
10.1
- Set Lock/Unlock scheme
Set the lock-unlock scheme for XM3 clock based lock-unlock switching.
Option
Value
Lock-to-unlock time marker
0
Unlock-to-lock time marker
1
Time markers must be entered as 4-digit decimal numbers representing a 24
hour time stamp in ‘hhmm’ format, e.g. 2359 = 23:59h.
Format
:
hours
Min. value
:
00
Max. value
:
24
Default value
:
00
Format
:
minutes
Min. value
:
00
Max. value
:
60
Default value
:
00
The time markers indicate the first minute during which access in the
respective time zone is possible. Setting the lock-to-unlock marker to 08:00h
and the unlock-to-lock marker to 17:00h means that then Unlock feature is
active from 08:00h until 16:59h and the Lock feature from 17:00h to 07.59h.
Setting both time markers to 00:00h disables the XM3 clock based time zone
switching (default setting).