2.2
Input and Output Signals -
Figure 2.2 shows the input and output connectors on the rear panel.
AC1
GND
J2 - RF OUTPUT A (COMMON)
SWITCH COMMON RF output.
Type N (female), 50
.
J7 - MONITORS and CONTROLS
Terminal Strip. See Table 2.1.
J1 - RF INPUT A1
SWITCH 1 RF input.
Type N (female), 50
.
AC1 - POWER IN 1
AC input for switching power supply.
100-240 ±10% VAC, 47-60 Hz.
AC2
J7
J1
A1
J2
A
J3
A2
1
14
AC2 - POWER IN 2
AC input for switching power supply.
100-240 ±10% VAC, 47-60 Hz.
J3 - RF INPUT A2
SWITCH 2 RF input.
Type N (female), 50
.
FIGURE 2.2 1582-650 RF Switch Rear Panel Inputs/Outputs
Table 2.1 J7 Pinouts (Monitors annd
Table 2.1 J7 Pinouts (Monitors and Controls)
Pin
Function
Description
1
REMOTE 1 IN
When in AUTO, momentary ground on this pin selects CH1
2
REMOTE 2 IN
When in AUTO, momentary ground on this pin selects CH2
3
GROUND
Ground
4
REMOTE RESET IN
When in LATCH mode, ground resets switch to CH1
5
NC
Not Connected
6
SWITCH COMMON
Common pin for SWITCH 1, 2
7
GROUND
Ground
8
MANUAL
*Open collector output (< 5
) to GND when in MANUAL mode
9
REMOTE
*Open collector (< 5
) to GND when in REMOTE mode
10
GROUND
Ground
11
SWITCH 1
**Relay closure to J7 pin 6 (<5
) when CH1 RF is selected
12
SWITCH 2
**Relay closure to J7 pin 6 (<5
) when CH2 RF is selected
13
ALARM 1 IN
Ground or Open (selectable by JP2) is CH1 alarm
14
ALARM 2 IN
Ground or Open (selectable by JP2) is CH2 alarm
* Max voltage to be connected is +20 VDC @ 30mA
** Max voltage to be connected is +30 VDC @ 100mA
*NOTE*
When the 1582 RF Switch is installed into a system, J7 Pins 13 and 14 (Alarms In) and
appropriate grounds must be interconnected between the primary(s), backup(s) and the 1582 RF Switch
for proper switch function.
2.3
Controls and Indicators -
The following are the front panel controls and indicators.
S1 - SWITCH RESET
Push-button resets switch to CH1 if it is good and
switch is in LATCH mode. Also resets REMOTE
selection to normal AUTO operation.
S3 - MANUAL SELECT
3-position switch manually selects CH1 or CH2 or
puts the unit in AUTO mode (switch position
determined by Alarm and Remote closures).
DS6 - CH1 ONLINE LED
Lights green when CH1 is
selected.
STATUS
ALARM
HISTORY
ALARM
SWITCH
MANUAL
SELECT
CH1
AUTO
CH2
CH2
ONLINE
MANUAL REMOTE
SWITCH
RESET
CH1
ONLINE
2
1
2
1
POWER
2
1
DS5 - CH2 ONLINE LED
Lights green when CH2 is
selected.
S2 - HISTORY RESET
Push-button resets ALARM
HISTORY LEDs only.
DS3 - MANUAL LED
Lights red when CH1 or
CH2 is manually
selected (using S3).
DS4 - REMOTE LED
Lights yellow when
remote control is active.
DS8,DS7 - ALARM LEDs
Light red when CH1 or CH2
alarm input is a closure or
open (selectable).
DS1,DS2 - ALM HIST LEDs
Light red on CH1,CH2 alarm,
and stay red until HISTORY
RESET is pressed.
DS9,DS10 - POWER LEDs
Light green when power is
applied to AC1, AC2.
HISTORY
RESET
1582-650 Manual, Rev. C
Page 6
01/26/10