background image

 FP3000 RAID 

USER'S

 

MANUAL

                                           

 

13

   

CROSS T.E.C  

www.crossups.com

 

 

5.

 

MAINTENANCE

 

&

 

SERVICE 

 

     

5.1.

 

Maintenance

 

&

 

Service 

                                                                         

-------

 

 

WARNING

   

-------------------------------------------------------- 

 

There

 

are

 

no

 

customer

 

servicable

 

units

 

inside. 

DO

 

NOT

 

open

 

the

 

cover

 

and

 

attempt

 

to

 

fix

 

the

 

unit.

   

High

 

voltage

 

may

 

remain

 

when

 

the

 

equipment

 

is

 

shut-off.

   

The

 

unauthorized

 

service

 

or

 

attempt

 

will

 

void

 

the

 

warranty

 

and

 

could

 

cause

 

the

 

serious

 

injury

 

and

 

the

 

costly

 

damage. 

 

------------------------------------------------------------------------------- 

 

     

The

 

possible

 

causes

 

for

 

the

 

abnormal

 

operation

 

of

 

UPS,

 

are

 

as

 

follows; 

 

             

5.1.1.

 

Input

 

power

 

out

 

of

 

operational

 

range. 

             

5.1.2.

 

Over-load

 

out

 

of

 

operational

 

range. 

             

5.1.3.

 

Ambient(surrounding)

 

condition

 

out

 

of

 

operational

 

range. 

             

5.1.4.

 

Misuse.

                         

             

5.1.5.

 

Component

 

failure. 

             

5.1.6.

 

etc. 

 

     

5.2.

 

Handling 

       

The

 

static

 

UPS

 

shall

 

be

 

treated

 

and

 

used

 

as

 

a

 

delicate

 

and

 

sensitive

 

equipment

 

like

 

computer

 

systems.

   

At

 

all

 

times,

 

adequate

 

operational

 

environment

 

shall

 

be

 

maintained

 

such

 

as

 

ambient

 

temperature

 

of

 

below

 

40    C,

 

clean

 

air,

 

sufficient

 

ventilation,

 

and

 

so

 

on. 

 

     

5.3.

 

Display

 

Panel

 

Reading 

       

Periodically,

 

checking

 

and

 

inspection

 

of

 

display

 

panel

 

reading

 

is

 

highly

 

recommended.

   

It

 

may

 

offer

 

the

 

clues

 

of

 

future

 

problem

 

and

 

may

 

provide

 

the

 

possible

 

preparations

 

of

 

foreseen

 

disaster. 

Also,

 

it

 

is

 

advised

 

to

 

read

 

the

 

display

 

panel

 

after

 

any

 

change

 

was

 

made

 

to

 

the

 

load,

 

input,

 

and

 

operation

 

of

 

the

 

system. 

 

 

 

 

 

 

Summary of Contents for FP3000

Page 1: ...FP3000 RAID USER S MANUAL 1 CROSS T E C www crossups com USER S MANUAL Frontier power 3000 UNINTERRUPTIBLE POWER SYSTEM CROSS T E C Co Ltd...

Page 2: ...ery 3 2 Installation 4 OPERATION PROCEDURE 4 1 Preoperational Requirement 4 2 Preparations 4 3 Operational Procedure 4 4 Ending Operation Procedure 4 5 Emergency Operation 5 MAINTENANCE AND SERVICES 5...

Page 3: ...onfident and widely known representative product The F3000 RAID Uninterruptible Power System of CROSS TEC is a truly advanced 3 phase on line sine wave UPS which Utilizes new power electronic technolo...

Page 4: ...sipation board and many other components It will convert input AC power to DC power supply the inverter and simultaneously charge the battery with the best condition possible Also the filtering circui...

Page 5: ...he moment of detection of any abnormal operation in inverter or over load condition the static switch will simultaneously transfer the power supply to bypass feed commercial power not to interrupt the...

Page 6: ...quency measurement for each phase 2 Operating condition Rectifier in operation RECT ON Rectifier out of operation RECT OFF Battery equalize charging EQU Battery float charging FLO Inverter in operatio...

Page 7: ...the battery stops to feed and starts to recharge At the same time the commercial power passes through the normal routine 2 3 4 Internal Failure Over load The output voltage and frequency of inverter...

Page 8: ...HASE 3 4 W RATED VOLTAGE 380V VOLTAGE STABILITY Within 2 RATED FREQUENCY 60 Hz 0 5 Hz VOLTAGE REGULATION Within 5 RESPONSE TIME Less Than 20mS VOLTAGE ADJUSTMENT Over 5 WAVEFORM DISTORTION Less than T...

Page 9: ...issing part or any visible damage If found any notify CROSS T E Co immediately Never apply any sharp edged material or tool to the equipment Avoid any form of physical shock to the equipment It may ca...

Page 10: ...t terminal battery cables need to be connected as well with enough care and concern about the positive and the negative cables Note All the connections are to be made FIRM 4 OPERATION PROCEDURE 4 1 Pr...

Page 11: ...ON 4 3 2 Turn the battery circuit breaker CB2 ON According to the amount of charging current detection FLO LED or EQU LED will light ON 4 3 3 PRESS ON button and ENABLE button simultaneously for the I...

Page 12: ...switch together to halt the INVERTER operation and to transfer to bypass mode 4 4 3 Turn OFF the battery circuit breaker CB2 4 4 4 Turn OFF the bypass circuit breaker CB4 4 4 5 Turn OFF the input cir...

Page 13: ...ational range 5 1 3 Ambient surrounding condition out of operational range 5 1 4 Misuse 5 1 5 Component failure 5 1 6 etc 5 2 Handling The static UPS shall be treated and used as a delicate and sensit...

Page 14: ...urement F To check the frequency measurement A To select the power condition of phase R B To select the power condition of phase S C To select the power condition of phase T ON To start the INVERTER o...

Page 15: ...intenance is required It is advisible to record the operational behavior in routine bases for smooth operation and easy service if necessary CATEGORY DESCRIPTION REMARK AC INPUT LED BYPASS INPUT LED I...

Page 16: ...N REMARK ANY DAMAGE ALARMING CONDITION LED INDICATIONS CIRCUIT BREAKERS STATUS LOAD CONDITION REPLACEMENT OTHER STATUS INPUT LINE INVERTER ON BYPASS ON FAULT BUZZER CONDITION SOLUTION ON ON Normal ON...

Page 17: ...ON Button 2 If no change call for service FAULT LED is ON Alarm sounds continuously 2 INPUT LINE LED is OFF 1 Possibly battery cut off 2 If the power recovers PRESS OFF RESET Button 3 If no change ca...

Page 18: ...l abuse improper installation unauthorized service or modification If it becomes necessary to send a defecting unit to CROSS T E Co the product shall be shipped in its original package or with adequat...

Reviews: