background image

 FP3000 RAID 

USER'S

 

MANUAL

                                           

 

3

   

CROSS T.E.C  

www.crossups.com

 

 

1.

 

INTRODUCTION 

 

                                                                               

First

 

of

 

all,

 

we

 

wish

 

to

 

thank

 

each

 

of

 

you

 

whom

 

purchases

 

our

 

premier

 

UPS

  F3000 

RAID  

of

 CROSS TEC

 

The

 

name

 

of

 Frontier 

was

 

originated

 

from

 

the

 

key

 

words

 

of

 

our

 

company

     

motto,

 

which

 

is

 

"We,

 

each

 

and

 

every

 

member

 

of

 CROSS TEC(

www.crossups.com

shall

 

head

   

toward

 

to

 

reach

 

the

 

top

 

in

 

the

 

field

 

as

 

we

 

try

 

together

 

with

 

the

 

original

 

idea

 

and

 

the

 

research

 

investment,

 

firmly

 

based

 

on

 

the

 

concord

 

and

 

the

 

sincerity

 

of

 

our

 

good

 

will"

.

   

Those

 

keywords

 

are

 

Electricity,

 

Sincerity,

 

Concord,

 

Original

 

idea,

 

Research

 

investment,

 

and

 

Top.

   

As

 

expressed

 

in

 

the

 

name

 

of

 FRONTIER 

itself,

 F3000 RAID

 

UPS

 

system

 

serves

 

as

 

the

 

guardian

 

of

 

all

 

the

 

sensitive

 

power

 

equipment

 

including

 

computers

 

&

 

telecommunication

 

systems

 

and

 

computerized

 

instruments,

 

and

 

as

 

well

 

as

 

our

 

confident

 

and

 

widely

 

known

 

representative

 

product. 

 

   

The

 F3000 RAID 

 

Uninterruptible

 

Power

 

System

 

of

 CROSS TEC

.

 

is

 

a

 

truly

 

advanced

 

3-phase

 

on-line

 

sine

 

wave

 

UPS

 

which

 

Utilizes

 

new

 

power

 

electronic

 

technology

 

such

 

as

 

Pulse

 

Width

 

Modulation

 

by

 

IGBT(Insulated

 

Gate

 

Bipolar

 

Transistor),

 

and

 

is

 

designed

 

to

 

offer

 

high

 

efficiency,

 

low

 

operational

 

noise,

 

compact

 

size,

 

better

 

reliability,

 

and

 

easy

 

access

 

for

 

maintenance

 

and

 

service

 

to

 

our

 

most

 

valuable

 

customer.

     

 

   

We

 

put

 

all

 

together

 

of

 

our

 

inspiration,

 

intuition,

 

energy,

 

effort,

 

and

 

resources

 

in

 

our

 

premier

 F3000

-3000

 

Uninterruptible

 

Power

 

Supply

 

System

 

 

 

2.

 

SYSTEM

 

DESCRIPTION 

 

     

2.1.

 

Foreword 

 

This

 

UPS

 

system

 

facilitates

 

sine

 

wave

 

Pulse

 

Width

 

Modulation

 

which

 

instantaneously

 

controls

 

the

 

waveform

 

to

 

supply

 

the

 

uninterrupted

 

constant

 

voltage

 

and

 

constant

 

frequency

 

balanced

 

3-phase

 

AC

 

power

 

to

 

the

 

critical

 

load

 

for

 

smooth

 

operation

 

and

 

fortified

 

protection

 

against

 

unstable

 

commercial

 

power

 

failure

 

such

 

as

 

outage,

 

sag,

 

surge,

 

voltage

 

transient,

 

frequency

 

change,

 

flicker,

 

and

 

etc. 

 

 

 

 

 

 

 

 

Summary of Contents for FP3000

Page 1: ...FP3000 RAID USER S MANUAL 1 CROSS T E C www crossups com USER S MANUAL Frontier power 3000 UNINTERRUPTIBLE POWER SYSTEM CROSS T E C Co Ltd...

Page 2: ...ery 3 2 Installation 4 OPERATION PROCEDURE 4 1 Preoperational Requirement 4 2 Preparations 4 3 Operational Procedure 4 4 Ending Operation Procedure 4 5 Emergency Operation 5 MAINTENANCE AND SERVICES 5...

Page 3: ...onfident and widely known representative product The F3000 RAID Uninterruptible Power System of CROSS TEC is a truly advanced 3 phase on line sine wave UPS which Utilizes new power electronic technolo...

Page 4: ...sipation board and many other components It will convert input AC power to DC power supply the inverter and simultaneously charge the battery with the best condition possible Also the filtering circui...

Page 5: ...he moment of detection of any abnormal operation in inverter or over load condition the static switch will simultaneously transfer the power supply to bypass feed commercial power not to interrupt the...

Page 6: ...quency measurement for each phase 2 Operating condition Rectifier in operation RECT ON Rectifier out of operation RECT OFF Battery equalize charging EQU Battery float charging FLO Inverter in operatio...

Page 7: ...the battery stops to feed and starts to recharge At the same time the commercial power passes through the normal routine 2 3 4 Internal Failure Over load The output voltage and frequency of inverter...

Page 8: ...HASE 3 4 W RATED VOLTAGE 380V VOLTAGE STABILITY Within 2 RATED FREQUENCY 60 Hz 0 5 Hz VOLTAGE REGULATION Within 5 RESPONSE TIME Less Than 20mS VOLTAGE ADJUSTMENT Over 5 WAVEFORM DISTORTION Less than T...

Page 9: ...issing part or any visible damage If found any notify CROSS T E Co immediately Never apply any sharp edged material or tool to the equipment Avoid any form of physical shock to the equipment It may ca...

Page 10: ...t terminal battery cables need to be connected as well with enough care and concern about the positive and the negative cables Note All the connections are to be made FIRM 4 OPERATION PROCEDURE 4 1 Pr...

Page 11: ...ON 4 3 2 Turn the battery circuit breaker CB2 ON According to the amount of charging current detection FLO LED or EQU LED will light ON 4 3 3 PRESS ON button and ENABLE button simultaneously for the I...

Page 12: ...switch together to halt the INVERTER operation and to transfer to bypass mode 4 4 3 Turn OFF the battery circuit breaker CB2 4 4 4 Turn OFF the bypass circuit breaker CB4 4 4 5 Turn OFF the input cir...

Page 13: ...ational range 5 1 3 Ambient surrounding condition out of operational range 5 1 4 Misuse 5 1 5 Component failure 5 1 6 etc 5 2 Handling The static UPS shall be treated and used as a delicate and sensit...

Page 14: ...urement F To check the frequency measurement A To select the power condition of phase R B To select the power condition of phase S C To select the power condition of phase T ON To start the INVERTER o...

Page 15: ...intenance is required It is advisible to record the operational behavior in routine bases for smooth operation and easy service if necessary CATEGORY DESCRIPTION REMARK AC INPUT LED BYPASS INPUT LED I...

Page 16: ...N REMARK ANY DAMAGE ALARMING CONDITION LED INDICATIONS CIRCUIT BREAKERS STATUS LOAD CONDITION REPLACEMENT OTHER STATUS INPUT LINE INVERTER ON BYPASS ON FAULT BUZZER CONDITION SOLUTION ON ON Normal ON...

Page 17: ...ON Button 2 If no change call for service FAULT LED is ON Alarm sounds continuously 2 INPUT LINE LED is OFF 1 Possibly battery cut off 2 If the power recovers PRESS OFF RESET Button 3 If no change ca...

Page 18: ...l abuse improper installation unauthorized service or modification If it becomes necessary to send a defecting unit to CROSS T E Co the product shall be shipped in its original package or with adequat...

Reviews: