 FP3000 RAID 

USER'S

 

MANUAL

                                           

 

7

   

CROSS T.E.C  

www.crossups.com

 

 

 

     

2.3.

 

Operation

   

 

           

2.3.1.

 

Normal 

               

The

 

rectifier

 

and

 

charger

 

will

 

get

 

the

 

AC

 

commercial

 

power

 

and

 

convert

 

it

 

to

 

DC,

 

and

 

then,

 

send

 

it

 

to

 

inverter

 

for

 

the

 

reverse

 

to

 

AC

 

and

 

to

   

battery

 

for

 

charging.

   

The

 

filtered

 

AC

 

power

 

from

 

inverter

 

will

 

be

   

supplied

 

to

 

the

 

load

 

without

 

interruption. 

 

           

2.3.2.

 

Power

 

Outage 

                     

When

 

commercial

 

power

 

fails,

 

the

 

battery

 

starts

 

to

 

let

 

out

 

the

 

reserved

       

DC

 

power

 

to

 

inverter

 

and

 

it

 

continues

 

to

 

feed

 

the

 

load

 

during

 

the

 

power

 

outage

 

for

 

the

 

defined

 

time

 

period. 

 

 

2.3.3.

 

Power

 

Recovery 

 

When

 

the

 

commercial

 

power

 

is

 

recovered,

 

the

 

battery

 

stops

 

to

 

feed

 

and

 

starts

 

to

 

recharge.

   

At

 

the

 

same

 

time,

 

the

 

commercial

 

power

 

passes

 

through

 

the

 

normal

 

routine. 

 

           

2.3.4.

 

Internal

 

Failure

 

&

 

Over-load 

               

The

 

output

 

voltage

 

and

 

frequency

 

of

 

inverter

 

are

 

synchronized

 

with

 

the

 

 

commercial

 

power

 

supply

 

at

 

all

 

times.

   

Thus,

 

in

 

case

 

of

 

internal

 

failure

 

or

 

over-load,

 

the

 

static

 

switch

 

transfers

 

power

 

to

 

bypass

 

feed

 

and

 

the

   

synchronized

 

power

 

is

 

constantly

 

fed

 

to

 

the

 

load. 

 

                                                                                                                                                       

       

 

 

FOR

 

THE

 

ELECTRICAL

 

CHARACTERISTICS

 

ON

 

PAGE

 

7. 

 

  

 

INPUT

 

VOLTAGE,

 

OUTPUT

 

VOLTAGE,

 

BATTERY

 

TYPE,

 

CAPACITY

 

(

 

BACK

               

-UP

 

TIME),

 

QUANTITY,

 

SHALL

 

BE

 

SPECIFIED

 

AT

 

TIME

 

OF

 

PURCHASE. 

 

   

*

       

:

   

When

 

power

 

outage,

 

input

 

power

 

varies,

 

or

 

0-100%

 

load

 

changes. 

   

**

     

:

   

At

 

rated

 

input/output,

 

and

 

rated

 

load. 

   

***

   

:

   

Control

 

circuits,

 

semi-conductors,

 

condensers,

 

and

 

noise

 

filters

 

are

 

excepted.

   

   

****

 

:

   

When

 

measured

 

from

 

1.5m

 

away,

 

and

 

1.5m

 

high.  

 

Summary of Contents for FP3000

Page 1: ...FP3000 RAID USER S MANUAL 1 CROSS T E C www crossups com USER S MANUAL Frontier power 3000 UNINTERRUPTIBLE POWER SYSTEM CROSS T E C Co Ltd...

Page 2: ...ery 3 2 Installation 4 OPERATION PROCEDURE 4 1 Preoperational Requirement 4 2 Preparations 4 3 Operational Procedure 4 4 Ending Operation Procedure 4 5 Emergency Operation 5 MAINTENANCE AND SERVICES 5...

Page 3: ...onfident and widely known representative product The F3000 RAID Uninterruptible Power System of CROSS TEC is a truly advanced 3 phase on line sine wave UPS which Utilizes new power electronic technolo...

Page 4: ...sipation board and many other components It will convert input AC power to DC power supply the inverter and simultaneously charge the battery with the best condition possible Also the filtering circui...

Page 5: ...he moment of detection of any abnormal operation in inverter or over load condition the static switch will simultaneously transfer the power supply to bypass feed commercial power not to interrupt the...

Page 6: ...quency measurement for each phase 2 Operating condition Rectifier in operation RECT ON Rectifier out of operation RECT OFF Battery equalize charging EQU Battery float charging FLO Inverter in operatio...

Page 7: ...the battery stops to feed and starts to recharge At the same time the commercial power passes through the normal routine 2 3 4 Internal Failure Over load The output voltage and frequency of inverter...

Page 8: ...HASE 3 4 W RATED VOLTAGE 380V VOLTAGE STABILITY Within 2 RATED FREQUENCY 60 Hz 0 5 Hz VOLTAGE REGULATION Within 5 RESPONSE TIME Less Than 20mS VOLTAGE ADJUSTMENT Over 5 WAVEFORM DISTORTION Less than T...

Page 9: ...issing part or any visible damage If found any notify CROSS T E Co immediately Never apply any sharp edged material or tool to the equipment Avoid any form of physical shock to the equipment It may ca...

Page 10: ...t terminal battery cables need to be connected as well with enough care and concern about the positive and the negative cables Note All the connections are to be made FIRM 4 OPERATION PROCEDURE 4 1 Pr...

Page 11: ...ON 4 3 2 Turn the battery circuit breaker CB2 ON According to the amount of charging current detection FLO LED or EQU LED will light ON 4 3 3 PRESS ON button and ENABLE button simultaneously for the I...

Page 12: ...switch together to halt the INVERTER operation and to transfer to bypass mode 4 4 3 Turn OFF the battery circuit breaker CB2 4 4 4 Turn OFF the bypass circuit breaker CB4 4 4 5 Turn OFF the input cir...

Page 13: ...ational range 5 1 3 Ambient surrounding condition out of operational range 5 1 4 Misuse 5 1 5 Component failure 5 1 6 etc 5 2 Handling The static UPS shall be treated and used as a delicate and sensit...

Page 14: ...urement F To check the frequency measurement A To select the power condition of phase R B To select the power condition of phase S C To select the power condition of phase T ON To start the INVERTER o...

Page 15: ...intenance is required It is advisible to record the operational behavior in routine bases for smooth operation and easy service if necessary CATEGORY DESCRIPTION REMARK AC INPUT LED BYPASS INPUT LED I...

Page 16: ...N REMARK ANY DAMAGE ALARMING CONDITION LED INDICATIONS CIRCUIT BREAKERS STATUS LOAD CONDITION REPLACEMENT OTHER STATUS INPUT LINE INVERTER ON BYPASS ON FAULT BUZZER CONDITION SOLUTION ON ON Normal ON...

Page 17: ...ON Button 2 If no change call for service FAULT LED is ON Alarm sounds continuously 2 INPUT LINE LED is OFF 1 Possibly battery cut off 2 If the power recovers PRESS OFF RESET Button 3 If no change ca...

Page 18: ...l abuse improper installation unauthorized service or modification If it becomes necessary to send a defecting unit to CROSS T E Co the product shall be shipped in its original package or with adequat...

Reviews: