AHRS500GA Series Operator’s Manual
Doc# 7430-0060-02 Rev. A
Page 15
5 Limitations
5.1
Installation
The AHRS500GA -202 must be mounted with the mounting plate facing
down into the gravitational field for correct operation.
The AHRS500GA -202 must be mounted in a location with limited
magnetic material near the unit. Refer to the installation manual for
detailed instructions.
5.2
Calibration
The AHRS500GA -202 must successfully complete a hard iron calibration
to reach full accuracy. Refer to the installation manual for detailed
instructions.
5.3
Operation
Magnetic material near the AHRS500GA
Introduction of large ferrous or magnetic material objects close to the
AHRS500GA -202, after calibration, will affect the heading performance.
Maintain at least 18 inches of distance between moving ferrous metal or
magnetic material and the AHRS500GA -202.
5.4
Range Limitations
The internal sensors in the AHRS500GA -202 are limited to maneuvers of
less than 200 degs/dec and less than 10 Gs acceleration in bank, pitch, and
heading. Over range of a sensor is indicated in the data packet message to
the display system. Over range will start a new initialization cycle of the
AHRS500GA and will require 90 seconds of straight and level flight to
reinitialize the AHRS500GA -202.
The AHRS500GA -202, like all magnetometer and magnetic compass-based
systems, will not perform properly at the magnetic North and South Poles.
The AHR500GA-202 will not operate properly in low gravitational fields
and magnetic fields encountered during space flight.