background image

12

 

Following press <

ENTER

>, the system displays the bypassed zones. 

 

 

 
While  in  the  Bypass  mode  it  is  possible  to  bypass  more  than  one  zone,  press 

<

BYPASS

>, Bypass indicator lights up to indicate that the system is in bypass mode, 

Add  the 

zone  number  (e.g.  03) 

one  or  more  zones,  following  press  <

ENTER

>  ,  the 

Bypass indicator lights up to indicate zone(s) bypassed . 
To  un-bypass  zones,  press  <

BYPASS

>,  enter 

zone  number  (e.g.07,13) 

and  press 

<

ENTER

>. 

Note

: Disarming automatically un-bypasses all zones. 

How to use Chime 

(

If enable by Installer) 

To disable  this function, press <

CHIME

> for 2 seconds, as shown below. 

 

 
To enable this function, press <CHIME> for 2 seconds, as shown below. 

 

 

 

Emergency Alerts 

How to initiate Panic 

Press simultaneously<

CHIME

>and <

CONTROL

> for 2 seconds. 

How to initiate Medical Alarm 

Press simultaneously <

CHIME

> and <

B

> for 2 seconds. 

How to initiate Fire Alarm 

Press simultaneously<

A

> and <

B

> for 2 seconds. 

Generate Threat or Duress 

If you are compelled  to  disarm  the system under threat, you must enter the duress digit 

before  the  user

s  code  to  activate  the  automatic  dialer.    The  duress  digit  shifts  up  your 

usual code by one digit.  If your code is 345 and 8 is your duress digit, than entering 8345 

will modify your code.  The modified duress code will disarm the system in a normal way, 

but  at  the  same  time  will  activate  the  dialer  silently  to  report  a 

duress  event

  without 

arousing suspicion. (For details ask installer.) 

Zone 3 Bypass 

Zone 3 

Chime OFF 

 

Chime ON 

 

www.msealarms.com.au

All manuals and user guides at all-guides.com

Summary of Contents for Power Wave CR16M

Page 1: ...v C N A Oct 2006 ELECTRONIC ENGINEERING LTD Power Wave CR16M LCD Keypad Users Operating and Programming Guide Version 2 00 www msealarms com au All manuals and user guides at all guides com a l l g u...

Page 2: ...t 9 How to Arm the System when Staying Home 10 How to Arm Partitions 11 How to Bypass Zones 11 How to use Chime If enable by Installer 12 Generate Threat or Duress 12 How to Read System Messages 13 Ho...

Page 3: ...ow to set Time and Date 17 How to operate the access control output 18 How to start Walk test Mode 18 How to Adjust Keypad Backlight Level 19 How to Adjust Buzzer Tone 20 PowerWave LCD Keypad Assignme...

Page 4: ...or and disarmed the garage from your cell phone so the white ware repairman can work on your washer The controller will support a 16 LED keypad or the more sophisticated LCD liquid Crystal Display key...

Page 5: ...nts to be displayed afterward on request to overview system activities and to analyze system performance for diagnostics The keyboard is illustrated in Figure 1 and the main components are detailed be...

Page 6: ...he LED indicators are listed in Table 2 Table 2 List of LED Indicators Design Function Bypass Indicates that there are bypassed zones Stay Indicates that the system is armed in STAY mode Armed Indicat...

Page 7: ...ds to arm relevant partition Only if enabled by installer Arm Stay STAY C O D E ENTER Initiates partial alarm when the user is home Only if enabled by installer Arm Stay STAY Initiates partial alarm w...

Page 8: ...trol for 2 seconds Change or Add Users code PROG M CODE ENTER Activates program mode to add or change Users codes For details see page 14 Customize keypad CONTROL ARM Enters Local Edit Program Mode Pr...

Page 9: ...l doors exits and windows are closed and motion in the protected area is restricted or bypassed If the green Ready indicator is not illuminated the LCD displays the open zones and descriptions Close o...

Page 10: ...System in Stay Mode This type of arming is used when people are present within the protected area At night time when the family is about to retire perimeter zones are protected but not the interior z...

Page 11: ...leave premises At the end of the procedure the ARMED indicator lights up to indicate that the system is armed and system message is displayed The indicators may go out after a few seconds depending o...

Page 12: ...ncy Alerts How to initiate Panic Press simultaneously CHIME and CONTROL for 2 seconds How to initiate Medical Alarm Press simultaneously CHIME and B for 2 seconds How to initiate Fire Alarm Press simu...

Page 13: ...re or abnormal events that may occur are indicated by trouble messages and the Trouble indicator is lit Press MEM to read out messages and other events stored in memory Trouble messages are listed in...

Page 14: ...ENT mode so you can add delete or change the user codes If you request it your installer can provide you with access to the INSTALLER mode as well To get into CLIENT mode provided the system is NOT ar...

Page 15: ...keyboard to enter your new Master code The code can hold any combination of 1 to 6 digits It is recommended using a multi digit code Press ENTER to save your new code To proceed to the next user code...

Page 16: ...for all of the addresses 1 8 998 999 you can also use the A button to return back to last saved text and you can use B button to return back to the default text Press ENTER to save textual descriptio...

Page 17: ...ENT mode To change the Time Date press In PW16 Press PROGRAM 823 ENTER 1 7 ENTER In PW4 8 Press PROGRAM 403 ENTER 1 7 ENTER In PW64 Press PROGRAM 678 ENTER 1 7 ENTER Where 1 7 the current day 1 Sun 2...

Page 18: ...are put into the memory buffer so they can be viewed at a later time To start Walk test mode while in CLIENT mode press PROGRAM 836 ENTER The keypad buzzer will beep at 1 second intervals Next trigge...

Page 19: ...How to Program Area Description While in Local Edit Program Mode Press PROG 998 and then ENTER You may edit any character one per each area To save changes press ENTER To update and transfer programm...

Page 20: ...increased to its maximum To decrease keyboard backlight hold CONTROL and press repeatedly until the light goes off How to Adjust Buzzer Tone The User can adjust the volume of the buzzer tone can be a...

Page 21: ...if the loss or damage is caused by Crow s own negligence or fault Crow does not represent that this product can not be compromised or circumvented that this product will prevent any person injury or p...

Page 22: ...ation Zone Zone Name 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 10 User Name Cont 10 11 31 11 12 32 12 13 33 13 14 34 14 15 35 15 16 36 16 17 37 18 38 19 39 20 40 21 41 22 42 23 43 24 44 25 4...

Page 23: ...notice Switch 8 MUST be left in the ON position Tamper Disabled i e Keypad Tamper Mode is reserved for future use Switch 1 Switch 2 Switch 3 Keypad 1 OFF OFF OFF Keypad 2 ON OFF OFF Keypad 3 OFF ON OF...

Page 24: ...24 www crowaust com au crow crowaust com au Oct 2006 www msealarms com au All manuals and user guides at all guides com...