Specifications
24
English
4. Specifications
Enclosure material
ADC 12 aluminium alloy
Dimension
156 x 166 x 109mm
(6.1 x 6.5 x 4.3inch)
Weight
Aluminium alloy 1kg (2.2lbs)
Cable entry
2x M20 (stopping plug fitted to left-side entry)
or supplied with ½” NPT adapters
Power
10-30Vdc. 3W max
Electrical output
4-20mA current sink or source
RS-485 Modbus RTU
HART (optional)
Relays
Alarm 1, Alarm 2, Fault
SPDT contacts rated 1A 24Vdc
Sounder Out:
MOSFET open-collector drive.
24Vdc (nominally), 0.7A maximum load
Operating temperature
-40°C to +70°C (-40°F to 158°F)
Note: sensor operating temperatures vary. Refer
to the sensor module datasheet or contact
Crowcon for specific sensor data.
Humidity
0 to 95% RH, non-condensing
Repeatability
+/- 2% FSD
Zero drift
+/- 2% FSD per year maximum
EMC compliance
EN50270:2015