background image

Only qualified service personnel shall perform installation and service.

 

 

 

2

• 

On highboy models,

 this panel will be the 

lower

 access panel on the 

front of the furnace. 

 

On lowboy models,

 remove the access panel at the 

rear

 of the furnace 

to reach the blower. 

 

On horizontal / counterflow models,

 this panel will be the 

upper

 access 

panel on the 

front

 of the furnace. 

 

3.  Locate the blower terminal block mounted on the scroll of the blower. 

Disconnect the three (3) lead wires that connect the furnace wiring harness 
cable to the terminal block. Temporarily tape, or tie back, out of the way the 
loose end of the wiring harness cable. 

 

4.  Remove the fasteners fixing the blower mounting angles or legs in place. 

Retain the fasteners for later reuse. 

 

• 

On highboy models,

 remove the burner access panel (located just above 

the blower access panel).  Then, remove two (2) sheet metal screws 
[located about seven (7) inches back from the front surface of the furnace] 
driven downward through the blower support panel, and into the support 
angles, refer to Figure 1. 

 

(Show depiction here of highboy blower compartment, blower assy., 
retaining screws, and mounting angles and rails. ID components) 

 

Figure 1: Blower Assembly Retaining Screw Locations on the 
Highboy Oil Furnace 

 

On lowboy models,

 remove two (2) sheet metal screws (and flat 

washers) driven downward through legs and into the base panel about 
three (3) inches back from the rear of the furnace, refer to Figure 2. 

 

(Show depiction here of lowboy blower compartment, blower assy., 
retaining hardware, blower mounting legs, motor grounding strap. ID 
components) 

 

Figure 2: Blower Assembly Retaining Screw Locations on the 
Lowboy Oil Furnace 

 

On horizontal / counterflow models,

 remove four (4) sheet metal 

screws [two (2) on either side of the bower scroll] driven downward 
through support angles and into the blower support panel, refer to  
Figure 3. 
 

Summary of Contents for CHB68-112

Page 1: ...if you find an oil leak DO NOT try to operate this appliance If possible close the manual fuel shutoff valve on the oil supply tank Immediately call your oil supplier Follow the oil supplier s instructions If you cannot reach your oil supplier call the fire department A qualified installer service agency or the oil supplier must perform installation and service These instructions should be read pr...

Page 2: ...Blower Motor Assembly WARNING If the heating system was recently operating allow the furnace to cool to room temperature before proceeding with disassembly WARNING BEFORE disconnecting the furnace wiring harness at the blower terminal block use a voltmeter or equivalent device to measure the electrical potential across the red and white wires and the orange and white wires at the terminal block No...

Page 3: ...nel Then remove two 2 sheet metal screws located about seven 7 inches back from the front surface of the furnace driven downward through the blower support panel and into the support angles refer to Figure 1 Show depiction here of highboy blower compartment blower assy retaining screws and mounting angles and rails ID components Figure 1 Blower Assembly Retaining Screw Locations on the Highboy Oil...

Page 4: ...tat ID components Figure 3 Blower Assembly Retaining Screw Locations on the Horizontal Counterflow Oil Furnace 5 Remove the entire blower motor assembly from the furnace Set it aside On highboy models pull forward and slide the blower out of the furnace On lowboy models lift up slightly and pull the blower out of the rear of the furnace o On horizontal counterflow models lift and pull the blower o...

Page 5: ...counterflow models set the blower down in the furnace and center it over the blower support panel opening 2 Reinstall the fasteners fixing the blower mounting angles or legs in place On highboy models align the holes in the support angles with the holes in the blower support panel Drive two 2 sheet metal screws downward through the blower support panel holes and into the holes in the support angle...

Page 6: ... ON 6 Adjust the room thermostat to cause the furnace to operate through at least one 1 complete heating or cooling cycle to test operation of the blower Setting the thermostat to the FAN or FAN ON position should cause the blower to run continuously on high speed 7 The blower should accelerate from rest to full speed within about ten 10 seconds or less Blower operation should be smooth without cl...