INSTALLATION AND OPERATION MANUAL, ROUND GAS COUNTER TILTING SKILLET,
MODEL GCTRS-16
PART NUMBER 10007R1
5
2004-06-23
1.0 SERVICE CONNECTIONS
(Continued)
Installation must conform with local codes, or in the absence of local codes, with the
National
Fuel Gas Code, ANSI Z223.1/NFPA 54
, or the
Natural Gas and Propane Installation Code,
CSA B149.1
, as applicable.
1.
The appliance and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at pressures in excess of ½ psi
(3.5 kPa).
2.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local
codes, with the National Electric Code ANS1/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
Ventilation must be provided in accordance with local codes, or in the absence of local codes,
with ANSI/SFPA 96 Standard for Ventilation and Fire Protection of Commercial cooker
Operations.
WARNING: Electrical grounding instructions - units equipped with a
three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding prong
from this plug. (120 volt units only).