8
CYLINDERS AND REGULATORS
LP GAS CYLINDER:
When purchasing a cylinder for your gas charbroiler, it must be constructed and marked
in accordance with the specifications of:
a) Canada - The Canadian Transport Commission
b) U.S.A. - The U.S. Department of Transportation
The cylinder must also be equipped with:
a) A shut-off valve terminating in a proper cylinder valve outlet specified in current
standards:
1) Canada: CAN/CGA - 1.6 - M88 - Outdoor Gas Grills - Amend. 1.
2) U.S.A.: ANSI/CGA-V-1-1977: Compressed gas cylinder valve outlet and inlet
connections.
b) A safety relief valve having direct communication with the vapour space of the cylinder.
c) A collar to protect the cylinder shut-off valve.
d) An arrangement for vapour withdrawal.
e) A bottom ring for securing to the cylinder support assembly.
WARNING!
• Always turn off the cylinder valve when your charbroiler is not in use.
• Handle cylinder valves with care.
• Never connect an unregulated LP gas cylinder to the charbroiler.
• Never store a spare cylinder under or near your charbroiler, or subject any cylinder to
excessive heat.
• Always keep cylinder(s) securely fastened in an upright position.
CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8
TEL: (519) 751-1800
FAX: (519) 751-1802
www.crownverity.com
Email: info@crownverity.com