1.0  INSTALLATION INSTRUCTIONS

INSTALLATION CODES AND STANDARDS

         

Installation must conform with local codes, or in the absence of local codes, with the 

National

 

Fuel Gas Code, ANSI Z223.1/NFPA 54

, or the  

Natural Gas and Propane 

Installation Code,

 

CSA B149.1

, as applicable.

1.

The appliance and its individual shut off valve must be disconnected from the gas 
supply piping system during any pressure testing of that system at pressures in
excess of ½ psi (3.5 kPa).

2.

The appliance must be isolated from the gas supply piping system by closing its 
individual manual shut off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ psi (3.5 kPa).

Electrical grounding must be provided in accordance with local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.2, as applicable.  

FLUE CONNECTIONS

     
Do not obstruct the flow of flue gases from the flue duct located on the rear of the gas fired
tilting skillet.  It is recommended that the flue gases be ventilated to the outside of the building
through a ventilation system installed by qualified personnel.

Information on the construction and installation of ventilating hoods may be obtained from the
standard for “Vapour Removal from Cooking Equipment”, NFPA No. 96 (latest edition),
available from the National Fire Protection Association, Batterymarch Park, Quincy, MA, U.S.A.
02269.  

UNPACKING

Immediately after unpacking, check for possible shipping damage.  If the gas fired tilting skillet
is found to be damaged, save the packaging material and contact the carrier within 15 days of
delivery.

Before installing, verify that the type of gas supply (natural or propane) and electrical service
agree with the specifications on the rating plate located on the left side console as you face the
front of the appliance.  If the supply and equipment requirements do not agree, contact your
dealer immediately.

Summary of Contents for GTS-30

Page 1: ...03 07 08 INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS GTS 30 GTS 40 CROWN FOOD SERVICE EQUIPMENT LTD 70 OAKDALE ROAD DOWNSVIEW TORONTO ONTARIO CANADA M3N 1V9 TELEPHONE 416 746 2358 FAX 416 74...

Page 2: ...smells gas must be posted in a prominent location This information shall be obtained by consulting the local gas supplier WARNING In the event you smell gas shut down equipment at the main shut off v...

Page 3: ...S 40 PART NUMBER 10093R2 3 2003 07 08 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes for Installation and Operation 2 Service Connections 4 1 0 Installation Instructions 5 2 0 Operating Instructio...

Page 4: ...INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS GTS 30 GTS 40 PART NUMBER 10093R2 4 2003 07 08...

Page 5: ...I NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable FLUE CONNECTIONS Do not obstruct the flow of flue gases from the flue duct located on the rear of the gas fired tilting skillet It is...

Page 6: ...penings into the combustion chamber must be provided Make sure there is an adequate supply of air in the room suitable for the amount of combustion gas feeding the burners Do not permit fans to blow d...

Page 7: ...adjustment is necessary Gas burner manifold is set at 3 5 W C Water Column for natural gas and 10 W C Water Column for propane gas After piping has been checked for leaks all piping receiving gas shou...

Page 8: ...d for Quick Disconnect Devices for Use with Gas Fuel ANSI Z21 41 CSA 6 9 adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconn...

Page 9: ...period must be observed prior to re establishing ignition source 1 Open the manual gas shut off valve located under the left hand console when facing the front of the unit 2 Ensure that the skillet p...

Page 10: ...OCEDURE 1 Turn skillet off turn thermostat dial to off turn power switch off 2 Close manual gas shut off valve TO TILT SKILLET 1 Lift lid 2 Turn handwheel clockwise to desired position 3 To return pan...

Page 11: ...k to pan surface Use mild detergent and water 3 Clean around burner air mixer and orifice if lint has accumulated 4 Visually assure carry over ports are unobstructed 5 Rinse entire unit and dry Do not...

Page 12: ...e is OFF Thermostat is not turned ON Pan not in lowest position Ignition control not functioning Unit electrical supply is not plugged in or turned on Burners produce carbon deposits Wrong size orific...