INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GTS-30, GTS-40
PART NUMBER 10093R2
6
2003-07-08
1.0 INSTALLATION INSTRUCTIONS
(Continued)
LOCATION
The equipment must be kept free and clear of combustible substances. The appliance, when
installed, must have minimum clearance from combustible and non-combustible construction of
0" from sides and 6" (152 mm) from the rear. The appliance is intended for use on non-
combustible floors.
The installation location must allow adequate clearances for servicing and proper operation. A
minimum front clearance of 36" (914 mm) is required.
The appliance must be installed so that the flow of combustion and ventilation air will not be
obstructed. Adequate clearance for air openings into the combustion chamber must be
provided. Make sure there is an adequate supply of air in the room suitable for the amount of
combustion gas feeding the burners.
Do not permit fans to blow directly at the appliance, and wherever possible, avoid open
windows next to the appliance. Avoid wall-type fans which create air cross currents within the
room.
LEVELLING AND ANCHORING
(For appliances not equipped with casters)
1. Set the appliance in place and level left to right and front-to-back using spirit level.
2. Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
3. Remove appliance and drill holes in locations marked on floor and insert proper anchoring
devices (not supplied).
4. Set unit back in position and re-level left to right and front to back.
5. Bolt and anchor appliance securely to the floor.
6. Seal bolts and flanged feet with silastic or equivalent compound.