SAM4s SPS-300 Operator's & Programming Manual v1.4
S-Mode Programming • 133
Flash ROM Updates
The SPS-300 series register software is loaded in flash ROM. This program may
occasionally be updated by the manufacturer. Your SAM4s dealer can update the software if
necessary.
The Flash ROM can be loaded through a PC Utility or by SD card.
CAUTION: Flash ROM update by either method must be done by a qualified, trained
technician. DO NOT POWER OFF OR ABORT any program loading once it has
started. Failure to follow the procedures exactly may cause the program to load
incompletely and for the register to fail completely.
Flash ROM Update by SD
The SPS-300 Flash ROM program is contained in a file named SPS300.bin. This file will be
provided to the authorized dealer by CRS, Inc. and contains both the Boot program area and
the Application program area.
1.
Create a folder named update in the root of the SD card.
2.
Copy SPS300.bin to: SD:/update/.
3.
Insert the SD card into the register. (The SD slot is located inside the printer
compartment. Remove the security screw and open the flap securing the SD slot.
Insert the SD card until you hear a click and the SD card is locked in.)
Boot Area Update
4.
At the SPS-300, turn the control lock to the
S
position.
5.
Power off the SPS-300.
6.
Press and hold the Numeral
1
key on the keyboard. While continuing to hold the
Numeral
1
key, turn on the power switch.
7.
A rapid beep-beep-beep will be heard. Release the Numeral
1
Key.
8.
The display the display will flash slowly at first and then will flash rapidly.
When the load is complete (about 5 seconds), a rapid beep-beep-beep will be
heard again the display will stop flashing and display a green color to confirm
update completion.
9.
Turn the ECR power switch OFF and proceed directly to the next step:
Application Update.
Application Area Update
10.
Set the control lock to the
S
position.
11.
Press and hold the Numeral
2
key on the keyboard. While continuing to hold the
Numeral
2
key, turn on the power switch.
12.
A rapid beep-beep-beep will be heard. Release the Numeral
2
Key.
13.
The display will flash (Current program is being erased), after a few seconds, the
display will continue to flash, but at a slower rate. This continues for about 1-
minute while the new program is being loaded. When the load is complete, a
Summary of Contents for Sam4s SPS-300 Series
Page 34: ...34 Getting Started SAM4s SPS 300 Operator s Programming Manual v1 4 ...
Page 92: ...92 Operations SAM4s SPS 300 Operator s Programming Manual v1 4 ...
Page 102: ...102 Management Functions SAM4s SPS 300 Operator s Programming Manual v1 4 ...
Page 246: ...246 Program Mode Programming SAM4s SPS 300 Operator s Programming Manual v1 4 ...
Page 282: ......