background image

millenium

 

    

                                                                               

                          

 MOBILE CB TRANSCEIVER  AM

FM

 

           

CITIZEN

  

BAND

 

EUROPEAN MULTI

-

NORMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                    

       

USER MANUAL 

                                       copyright 

CRT France 2017 

 

    

 

                 

 

 

Downloaded from www.cbradio.nl

Summary of Contents for Millenium

Page 1: ...millenium MOBILE CB TRANSCEIVER AM FM CITIZENBANDEUROPEAN MULTI NORMS USER MANUAL copyright CRT France 2017 Downloaded from www cbradio nl ...

Page 2: ......

Page 3: ...2 ...

Page 4: ...3 ...

Page 5: ...Up down keys on the microphone Scan channel LCD display Auto ASQ SQ adjustable RF GAIN External Speaker 2 Installation instructions Check the materials before the installation car charger is connected to the car s 12 v power supply socket the radio s positive and negative electrode connected to the car charger s Power supply support 12 V to 13 8 V Check all wiring are in good condition before star...

Page 6: ...5 3 Control panel function Front view No Name Short Press Function Long Press Function Microphone socket A F AM FM Mode Switch Scan Function LCD Display Power On Off Volume ...

Page 7: ...nterclockwise until it clicks The radio is power off 4 2 Volume Control Turn clockwise to increase volume turn counterclockwise to decreases volume 4 3 Channel Selection 1 Shortly press microphone UP or DOWN to change working channel Channel UP DOWN select EMG Emergen cy Channel 9 19 Channel Switch RFG Enter RF GAIN Model SQ ASQ Function Switch Enter SQ ASQ Level Switch Switch To ASQ Mode ...

Page 8: ... SQ off 0 1 Lowest SQ level 2 8 Highest SQ level 2 Press microphone UP DOWN shortly to change SQ level 3 Hold microphone UP DOWN to change the SQ level fast 4 Hold SQ or wait for 3 seconds to store and exit 4 5 ASQ control 9 level 1 Hold SQ key until LCD display AQ the ASQ function is turned on The LCD will display A X X stands for the ASQ level A 1 Lowest ASQ level A 9 Highest ASQ level ...

Page 9: ...s the selected mode 4 7 RF GAIN control 1 Shortly press RFG key LCD displays R and the present RF GAIN level flashes 2 Shortly press microphone UP DOWN to change the level 3 Shortly press RFG key to exit RF GAIN level control 4 8 Emergency Channel 1 Shortly press EMG key to choose CH9 the channel number flashes 2 Shortly press EMG key again to choose CH19 the channel number flashes 3 Shortly press...

Page 10: ...C 2 Press microphone UP DOWN can choose scanning clockwise or counterclockwise 3 Press A F or PTT key to exit scan function 4 11 Changing the CB Standard 1 Hold A F while powering the radio on until LCD displays the norms 2 Press microphone UP DOWN to choose wanted Norms 3 Power off and power on again Standard Channels Fequency Range EU 40FM 40AM 26 965 27 405MHZ CE 40 FM 26 965 27 405MHZ UK 40 FM...

Page 11: ... DE 40FM 40AM 26 965 27 405MHZ 80FM 26 565 26 955MHZ IN 27FM 27AM 26 965 27 275MHZ 4 12 Restore factory default 1 Hold SQ key while powering the radio on until the LCD displays rt 2 All channel and function setting will resume factory default after above operation ...

Page 12: ...11 ...

Page 13: ...12 ...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Page 17: ... use CROATIA YES 40 ch 4 W FM free use AM Not authorized EC DANEMARK YES 40 ch 4 W FM free use AM Not authorized EC SPAIN YES 40 ch 4 W FM individual license required E EC EU 40 ch 4 W AM individual license required 12 W pep BLU SSB ESTONIA YES 40 ch 4 W FM free use EU EC 40 ch 4 W AM free use FINLAND YES 40 ch 4 W FM free use EU EC 40 ch 4 W AM free use FRANCE YES 40 ch 4 W FM free use EU EC 40 c...

Page 18: ...ot authorized EC NETHERLAND YES 40 ch 4 W FM free use EU EC 40 ch 4 W AM free use POLAND YES 40 ch 4 W FM free use EC 40 ch 4 W AM FM free use PL 12 W pep BLU SSB PORTUGAL YES 40 ch 4 W FM free use EU EC 40 ch 4 W AM free use CZECH YES 80 ch 4 W FM free use AM Not authorized EC ROMANIA YES 40 ch 4 W FM free use EU EC 40 ch 4 W AM free use SLOVAKIA YES 40 ch 4 W FM free use AM Not authorized EC SLO...

Page 19: ...tive R TTE 1 999 5 CE european standarts EN 60950 1 A1 A11 A12 A2 EN 301489 1 V 1 9 2 EN 301489 13 V 1 2 1 EN 300433 1 V 1 3 1 EN 300433 2 V 1 3 1 EN 30 0 135 1 V 1 2 1 EN 30 0 135 2 V 1 2 1 EMF EN 62311 C R T FRANCE INTERNATIONAL S A R L Route de Pagny 21250 SEURRE FRANCE Capital de 762 500 euros Tél 03 80 26 91 91 Fax 03 80 26 91 00 E mail superstar crtfrance com Web site www crtfrance com Mr CE...

Page 20: ...f polarity surge bad connection etc recognized by our technical service The interventions having modified the standards of approval of the device PROCEDURE ON RETURNING TO THE AFTER SALES SERVICE CRT If you send back a radio under guarantee for repair You must pay the freight costs to go CRT will pay the freight costs return If the radio is not under guarantee postal charges are at your expense Eac...

Reviews: